↓ Skip to main content

Determination of loss of consciousness

Overview of attention for article published in European Journal of Anaesthesiology, December 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
51 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Determination of loss of consciousness
Published in
European Journal of Anaesthesiology, December 2016
DOI 10.1097/eja.0000000000000532
Pubmed ID
Authors

Eva-Lena Zetterlund, Henrik Gréen, Anna Oscarsson, Svante Vikingsson, Magnus Vrethem, Maj-Lis Lindholm, Christina Eintrei

Abstract

Computer-processed algorithms of encephalographic signals are widely used to assess the depth of anaesthesia. However, data indicate that the bispectral index (BIS), a processed electroencephalography monitoring system, may not be reliable for assessing the depth of anaesthesia. The aim of this study was to evaluate the ability of the BIS monitoring system to assess changes in the level of unconsciousness, specifically during the transition from consciousness to unconsciousness, in patients undergoing total intravenous anaesthesia with propofol. We compared BIS with the electroencephalogram (EEG), and clinical loss of consciousness (LOC) defined as loss of verbal commands and eyelash reflex. This was an observational cohort study. University Hospital Linköping, University Hospital Örebro, Finspång Hospital and Kalmar Hospital, Sweden from October 2011 to April 2013. A total of 35 ASA I patients aged 18 to 49 years were recruited. The patients underwent total intravenous anaesthesia with propofol and remifentanil for elective day-case surgery. Changes in clinical levels of consciousness were assessed by BIS and compared with assessment of stage 3 neurophysiological activity using the EEG. The plasma concentrations of propofol were measured at clinical LOC and 20 and 30 min after LOC. The primary outcome was measurement of BIS, EEG and clinical LOC. The median BIS value at clinical LOC was 38 (IQR 30 to 43), and the BIS values varied greatly between patients. There was no correlation between BIS values and EEG stages at clinical LOC (r = -0.1, P = 0.064). Propofol concentration reached a steady state within 20 min. There was no statistically significant correlation between BIS and EEG at clinical LOC. BIS monitoring may not be a reliable method for determining LOC. This trial was not registered because registration was not mandatory at the time of the trial.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Korea, Republic of 1 2%
Unknown 50 98%

Demographic breakdown

Readers by professional status Count As %
Other 6 12%
Professor 5 10%
Student > Ph. D. Student 4 8%
Researcher 4 8%
Student > Doctoral Student 3 6%
Other 11 22%
Unknown 18 35%
Readers by discipline Count As %
Medicine and Dentistry 19 37%
Nursing and Health Professions 3 6%
Unspecified 2 4%
Engineering 2 4%
Biochemistry, Genetics and Molecular Biology 1 2%
Other 6 12%
Unknown 18 35%