↓ Skip to main content

Robotic and laparoendoscopic single-site utero-sacral ligament suspension for apical vaginal prolapse: evaluation of our technique and perioperative outcomes

Overview of attention for article published in Journal of Robotic Surgery, September 2016
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (67th percentile)
  • Good Attention Score compared to outputs of the same age and source (73rd percentile)

Mentioned by

twitter
6 X users

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
53 Mendeley
Title
Robotic and laparoendoscopic single-site utero-sacral ligament suspension for apical vaginal prolapse: evaluation of our technique and perioperative outcomes
Published in
Journal of Robotic Surgery, September 2016
DOI 10.1007/s11701-016-0638-0
Pubmed ID
Authors

Hugo H Davila, Taryn Gallo, Lindsey Bruce, Christopher Landrey

Abstract

The objective of this study was to evaluate our technique and steps of robotic and laparoendoscopic single-site utero-sacral ligament suspension in the treatment of patients with symptomatic apical vaginal prolapse. A retrospective analysis was done using the data in 2 community hospital. Eighteen women presented with vaginal apex prolapse and desired minimally invasive surgery (video): (a) Laparoendoscopic single-site utero-sacral ligament suspension (LESS-UTSLS) (n = 13) or (b) robotic-assisted single-site utero-sacral ligament suspension (RASS-UTSLS) (n = 5) were eligible to participate. All participants underwent a standardized evaluation, including a structured urogynecologic history and physical examination with pelvic organ prolapse quantitative stage. Participants also completed validated questionnaire about pain scale. Multiples perioperative values were obtained to evaluate our minimally invasive approach. There were no differences in demographic, pre-operative anatomic, and functional data between groups. Concomitant anti-incontinence surgery with trans-obturator tape among the LESS-UTSLS vs RASS-UTSLS groups was performed in 2 (15 %) compared with 0 (0 %) and vaginal hysterectomy 2 (15 %) compared with supracervical hysterectomy 2 (40 %), respectively. The UTSLS operating time was similar in the RASS group compared with the LESS group (difference 9 min. There were only one POP (8 %) recurrence (stage 3) and one umbilical hernia (8 %) in the LESS-UTSLS group after 12 months of surgery. Two patients (15 %) developed stress urinary incontinence after LESS-UTSLS. We presented our technique and perioperative outcomes. RASS-UTSLS was similar operative times to LESS UTSL (+9 min), no differences in post-operative pain, anatomic support, or complications 6 months. We found that robotic surgical systems may accelerate the learning curve in the single-site surgery. Future investigations are warranted to discern the best applications for robotic single site technology in benign gynecologic surgery.

X Demographics

X Demographics

The data shown below were collected from the profiles of 6 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 53 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Denmark 1 2%
Unknown 52 98%

Demographic breakdown

Readers by professional status Count As %
Student > Master 8 15%
Student > Doctoral Student 6 11%
Other 4 8%
Unspecified 4 8%
Student > Ph. D. Student 4 8%
Other 16 30%
Unknown 11 21%
Readers by discipline Count As %
Medicine and Dentistry 21 40%
Unspecified 4 8%
Nursing and Health Professions 3 6%
Agricultural and Biological Sciences 2 4%
Engineering 2 4%
Other 5 9%
Unknown 16 30%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 4. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 May 2017.
All research outputs
#6,920,812
of 22,886,568 outputs
Outputs from Journal of Robotic Surgery
#166
of 679 outputs
Outputs of similar age
#107,123
of 332,538 outputs
Outputs of similar age from Journal of Robotic Surgery
#4
of 15 outputs
Altmetric has tracked 22,886,568 research outputs across all sources so far. This one has received more attention than most of these and is in the 69th percentile.
So far Altmetric has tracked 679 research outputs from this source. They receive a mean Attention Score of 3.7. This one has done well, scoring higher than 75% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 332,538 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 67% of its contemporaries.
We're also able to compare this research output to 15 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 73% of its contemporaries.