Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?

Overview of attention for article published in European Journal of Trauma and Emergency Surgery, October 2016
Altmetric Badge

Mentioned by

twitter
4 X users

Citations

dimensions_citation
75 Dimensions

Readers on

mendeley
115 Mendeley
Title
Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?
Published in
European Journal of Trauma and Emergency Surgery, October 2016
DOI 10.1007/s00068-016-0738-6
Pubmed ID
Authors

L. Maini, A. Sharma, S. Jha, A. Sharma, A. Tiwari

Abstract

Due to the complexity of acetabulum, achieving anatomical contouring intra-operatively is difficult for surgeon. A 3D (dimensional) real model can facilitate us both in contouring the plate pre-operatively and in better pre-operative planning. Patient-specific pre-contoured plate in acetabular fracture has been studied by few researchers but randomized case-control study was lacking. Hence, we conducted a case-control study to evaluate the accuracy of patient-specific pre-contoured plate. Prospective randomized case control study was conducted. 21 patients were included. 10 patients were distributed in "case" group and remaining 11 in "control" group. Displaced acetabulum fractures with displacement of ≥3 mm in adults who reported within 3 weeks of injury. Exclusion criteria were: Open fractures, associated Morel-Lavallée lesion and patients with >3 weeks old fracture. In case group, patient-specific real 3D model of fractured acetabulum was generated using rapid prototyping technology and plates were contoured pre-operatively. Control group was treated using intra-operative contoured plates. Both the groups were compared using parameters: Blood loss, Surgery time, post-operative reduction on X-ray, post-surgical residual displacement and reduction achieved as evaluated by CT scan. Reduced blood loss (100 ml less in case group) and surgical time (12 min less in case group) and better post-operative reduction were observed in case than control. In control group, 4 patients even had step of 2-3 mm, which was not seen in case group. All the pre-contoured plates fitted well to the pelvis intra-operatively. Reduction achieved as evaluated by CT was more in "case" group with statistically significant outcomes (p < 0.05). Patient-specific pre-contoured plate made using 3D model is a better implant than intra-operatively contoured plate. Real-time 3D pelvis model is an accurate technique for pre-operative planning in acetabular fractures.

X Demographics

X Demographics

The data shown below were collected from the profiles of 4 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 115 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 115 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 17 15%
Student > Master 15 13%
Student > Postgraduate 12 10%
Student > Bachelor 12 10%
Student > Doctoral Student 11 10%
Other 23 20%
Unknown 25 22%
Readers by discipline Count As %
Medicine and Dentistry 47 41%
Engineering 11 10%
Biochemistry, Genetics and Molecular Biology 3 3%
Nursing and Health Professions 2 2%
Computer Science 2 2%
Other 15 13%
Unknown 35 30%