↓ Skip to main content

Epistaxis during nasotracheal intubation: a randomized trial of the Parker Flex-Tip™ nasal endotracheal tube with a posterior facing bevel versus a standard nasal RAE endotracheal tube

Overview of attention for article published in Canadian Journal of Anesthesia/Journal canadien d'anesthésie, January 2017
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (81st percentile)
  • Good Attention Score compared to outputs of the same age and source (68th percentile)

Mentioned by

twitter
14 X users

Citations

dimensions_citation
14 Dimensions

Readers on

mendeley
6 Mendeley
Title
Epistaxis during nasotracheal intubation: a randomized trial of the Parker Flex-Tip™ nasal endotracheal tube with a posterior facing bevel versus a standard nasal RAE endotracheal tube
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie, January 2017
DOI 10.1007/s12630-017-0813-4
Pubmed ID
Authors

Rosie Earle, Enda Shanahan, Himat Vaghadia, Andrew Sawka, Raymond Tang

Abstract

Nasotracheal intubation is a widely performed technique to facilitate anesthesia induction during oral, dental, and maxillofacial surgeries. The technique poses several risks not encountered with oropharyngeal intubation, most commonly epistaxis due to nasal mucosal abrasion. The purpose of this study was to test whether the use of the Parker Flex-Tip™ (PFT) nasal endotracheal tube (ETT) with a posterior facing bevel reduces epistaxis when compared with the standard nasal RAE ETT with a leftward facing bevel. Sixty American Society of Anesthesiologists physical status I and II patients undergoing oral or maxillofacial surgery with nasotracheal intubation were recruited. Patients were randomized to either a standard nasal RAE ETT or a PFT nasal ETT. The ETT was thermosoftened and lubricated for both study groups prior to insertion, and the size of the tube was chosen at the discretion of the attending anesthesiologist. The primary outcome was the incidence of epistaxis, with a secondary outcome of epistaxis severity (scored as none, mild, moderate, or severe). An investigator measured both outcomes five minutes after intubation was completed. Mild or moderate epistaxis was experienced by 22 of 30 (73%) patients in the PFT group compared with 21 of 30 (70%) patients in the standard nasal RAE ETT group (absolute risk reduction, 3%; 95% confidence interval, -19 to 25; P = 0.78). There were no occurrences of severe epistaxis in either group. There was no difference in the incidence or severity of epistaxis following nasal intubation using the Parker Flex-Tip nasal ETT when compared with a standard nasal RAE ETT. This trial was registered at ClinicalTrials.gov, identifier: NCT02315677.

X Demographics

X Demographics

The data shown below were collected from the profiles of 14 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 6 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 6 100%

Demographic breakdown

Readers by professional status Count As %
Student > Postgraduate 2 33%
Other 1 17%
Student > Master 1 17%
Unknown 2 33%
Readers by discipline Count As %
Medicine and Dentistry 4 67%
Unknown 2 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 9. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 April 2017.
All research outputs
#4,192,356
of 25,374,917 outputs
Outputs from Canadian Journal of Anesthesia/Journal canadien d'anesthésie
#663
of 2,878 outputs
Outputs of similar age
#76,568
of 423,602 outputs
Outputs of similar age from Canadian Journal of Anesthesia/Journal canadien d'anesthésie
#15
of 47 outputs
Altmetric has tracked 25,374,917 research outputs across all sources so far. Compared to these this one has done well and is in the 83rd percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 2,878 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 9.6. This one has done well, scoring higher than 76% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 423,602 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 81% of its contemporaries.
We're also able to compare this research output to 47 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 68% of its contemporaries.