↓ Skip to main content

T2‐weighted 3D fMRI using S2‐SSFP at 7 tesla

Overview of attention for article published in Magnetic Resonance in Medicine, March 2010
Altmetric Badge

Citations

dimensions_citation
36 Dimensions

Readers on

mendeley
51 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
T2‐weighted 3D fMRI using S2‐SSFP at 7 tesla
Published in
Magnetic Resonance in Medicine, March 2010
DOI 10.1002/mrm.22283
Pubmed ID
Authors

Markus Barth, Heiko Meyer, Stephan A. R. Kannengiesser, Jonathan R. Polimeni, Lawrence L. Wald, David G. Norris

Abstract

In this study, the sensitivity of the S(2)-steady-state free precession (SSFP) signal for functional MRI at 7 T was investigated. In order to achieve the necessary temporal resolution, a three-dimensional acquisition scheme with acceleration along two spatial axes was employed. Activation maps based on S(2)-steady-state free precession data showed similar spatial localization of activation and sensitivity as spin-echo echo-planar imaging (SE-EPI), but data can be acquired with substantially lower power deposition. The functional sensitivity estimated by the average z-values was not significantly different for SE-EPI compared to the S(2)-signal but was slightly lower for the S(2)-signal (6.74 +/- 0.32 for the TR = 15 ms protocol and 7.51 +/- 0.78 for the TR = 27 ms protocol) compared to SE-EPI (7.49 +/- 1.44 and 8.05 +/- 1.67) using the same activated voxels, respectively. The relative signal changes in these voxels upon activation were slightly lower for SE-EPI (2.37% +/- 0.18%) compared to the TR = 15 ms S(2)-SSFP protocol (2.75% +/- 0.53%) and significantly lower than the TR = 27 ms protocol (5.38% +/- 1.28%), in line with simulations results. The large relative signal change for the long TR SSFP protocol can be explained by contributions from multiple coherence pathways and the low intrinsic intensity of the S(2) signal. In conclusion, whole-brain T(2)-weighted functional MRI with negligible image distortion at 7 T is feasible using the S(2)-SSFP sequence and partially parallel imaging.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Germany 2 4%
United States 1 2%
Unknown 48 94%

Demographic breakdown

Readers by professional status Count As %
Researcher 18 35%
Student > Ph. D. Student 11 22%
Student > Master 6 12%
Professor > Associate Professor 5 10%
Professor 4 8%
Other 5 10%
Unknown 2 4%
Readers by discipline Count As %
Engineering 13 25%
Neuroscience 10 20%
Medicine and Dentistry 9 18%
Physics and Astronomy 6 12%
Agricultural and Biological Sciences 3 6%
Other 3 6%
Unknown 7 14%