↓ Skip to main content

The SmartOR: a distributed sensor network to improve operating room efficiency

Overview of attention for article published in Surgical Endoscopy, February 2017
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (71st percentile)
  • High Attention Score compared to outputs of the same age and source (80th percentile)

Mentioned by

twitter
12 X users

Citations

dimensions_citation
16 Dimensions

Readers on

mendeley
46 Mendeley
Title
The SmartOR: a distributed sensor network to improve operating room efficiency
Published in
Surgical Endoscopy, February 2017
DOI 10.1007/s00464-016-5390-z
Pubmed ID
Authors

Albert Y. Huang, Guillaume Joerger, Vid Fikfak, Remi Salmon, Brian J. Dunkin, Barbara L. Bass, Marc Garbey

Abstract

Despite the significant expense of OR time, best practice achieves only 70% efficiency. Compounding this problem is a lack of real-time data. Most current OR utilization programs require manual data entry. Automated systems require installation and maintenance of expensive tracking hardware throughout the institution. This study developed an inexpensive, automated OR utilization system and analyzed data from multiple operating rooms. OR activity was deconstructed into four room states. A sensor network was then developed to automatically capture these states using only three sensors, a local wireless network, and a data capture computer. Two systems were then installed into two ORs, recordings captured 24/7. The SmartOR recorded the following events: any room activity, patient entry/exit time, anesthesia time, laparoscopy time, room turnover time, and time of preoperative patient identification by the surgeon. From November 2014 to December 2015, data on 1003 cases were collected. The mean turnover time was 36 min, and 38% of cases met the institutional goal of ≤30 min. Data analysis also identified outlier cases (>1 SD from mean) in the domains of time from patient entry into the OR to intubation (11% of cases) and time from extubation to patient exiting the OR (11% of cases). Time from surgeon identification of patient to scheduled procedure start time was 11 min (institution bylaws require 20 min before scheduled start time), yet OR teams required 22 min on average to bring a patient into the room after surgeon identification. The SmartOR automatically and reliably captures data on OR room state and, in real time, identifies outlier cases that may be examined closer to improve efficiency. As no manual entry is required, the data are indisputable and allow OR teams to maintain a patient-centric focus.

X Demographics

X Demographics

The data shown below were collected from the profiles of 12 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 46 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 46 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 9 20%
Student > Ph. D. Student 6 13%
Student > Postgraduate 5 11%
Other 4 9%
Researcher 4 9%
Other 8 17%
Unknown 10 22%
Readers by discipline Count As %
Medicine and Dentistry 16 35%
Engineering 7 15%
Nursing and Health Professions 6 13%
Computer Science 1 2%
Pharmacology, Toxicology and Pharmaceutical Science 1 2%
Other 2 4%
Unknown 13 28%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 6. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 11 September 2017.
All research outputs
#5,541,850
of 25,703,943 outputs
Outputs from Surgical Endoscopy
#903
of 6,940 outputs
Outputs of similar age
#91,031
of 325,814 outputs
Outputs of similar age from Surgical Endoscopy
#23
of 118 outputs
Altmetric has tracked 25,703,943 research outputs across all sources so far. Compared to these this one has done well and is in the 75th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 6,940 research outputs from this source. They receive a mean Attention Score of 4.0. This one has done well, scoring higher than 85% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 325,814 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 71% of its contemporaries.
We're also able to compare this research output to 118 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 80% of its contemporaries.