↓ Skip to main content

Tips and tricks for a safe and effective image-guided percutaneous renal tumour ablation

Overview of attention for article published in Insights into Imaging, May 2017
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (79th percentile)
  • Above-average Attention Score compared to outputs of the same age and source (55th percentile)

Mentioned by

blogs
1 blog
twitter
3 X users

Citations

dimensions_citation
59 Dimensions

Readers on

mendeley
46 Mendeley
Title
Tips and tricks for a safe and effective image-guided percutaneous renal tumour ablation
Published in
Insights into Imaging, May 2017
DOI 10.1007/s13244-017-0555-4
Pubmed ID
Authors

Giovanni Mauri, L. Nicosia, G. M. Varano, G. Bonomo, P. Della Vigna, L. Monfardini, F. Orsi

Abstract

Image-guide thermal ablations are nowadays increasingly used to provide a minimally invasive treatment to patients with renal tumours, with reported good clinical results and low complications rate. Different ablative techniques can be applied, each with some advantages and disadvantages according to the clinical situation. Moreover, percutaneous ablation of renal tumours might be complex in cases where there is limited access for image guidance or a close proximity to critical structures, which can be unintentionally injured during treatment. In the present paper we offer an overview of the most commonly used ablative techniques and of the most important manoeuvres that can be applied to enhance the safety and effectiveness of percutaneous image-guided renal ablation. Emphasis is given to the different technical aspects of cryoablation, radiofrequency ablation, and microwave ablation, on the ideal operating room setting, optimal image guidance, application of fusion imaging and virtual navigation, and contrast enhanced ultrasound in the guidance and monitoring of the procedure. Moreover, a series of protective manoeuvre that can be used to avoid damage to surrounding sensitive structures is presented. A selection of cases of image-guided thermal ablation of renal tumours in which the discussed technique were used is presented and illustrated. • Cryoablation, radiofrequency and microwave ablation have different advantages and disadvantages. • US, CT, fusion imaging, and CEUS increase an effective image-guidance. • Different patient positioning and external compression may increase procedure feasibility. • Hydrodissection and gas insufflation are useful to displace surrounding critical structures. • Cold pyeloperfusion can reduce the thermal damage to the collecting system.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 46 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 46 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 8 17%
Student > Postgraduate 7 15%
Student > Ph. D. Student 5 11%
Other 4 9%
Researcher 4 9%
Other 8 17%
Unknown 10 22%
Readers by discipline Count As %
Medicine and Dentistry 25 54%
Unspecified 1 2%
Pharmacology, Toxicology and Pharmaceutical Science 1 2%
Immunology and Microbiology 1 2%
Nursing and Health Professions 1 2%
Other 2 4%
Unknown 15 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 9. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 14 March 2019.
All research outputs
#3,843,783
of 24,217,893 outputs
Outputs from Insights into Imaging
#215
of 1,072 outputs
Outputs of similar age
#64,575
of 313,749 outputs
Outputs of similar age from Insights into Imaging
#4
of 9 outputs
Altmetric has tracked 24,217,893 research outputs across all sources so far. Compared to these this one has done well and is in the 84th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 1,072 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 7.2. This one has done well, scoring higher than 79% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 313,749 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 79% of its contemporaries.
We're also able to compare this research output to 9 others from the same source and published within six weeks on either side of this one. This one has scored higher than 5 of them.