↓ Skip to main content

Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study

Overview of attention for article published in European Radiology, August 2017
Altmetric Badge

Mentioned by

twitter
3 X users

Citations

dimensions_citation
20 Dimensions

Readers on

mendeley
33 Mendeley
Title
Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
Published in
European Radiology, August 2017
DOI 10.1007/s00330-017-4984-8
Pubmed ID
Authors

Virgile Chevance, Thibaud Damy, Vania Tacher, François Legou, Fourat Ridouani, Alain Luciani, Hicham Kobeiter, Alain Rahmouni, Jean-François Deux

Abstract

To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. IVS thickness was significantly (p < 0.001) higher in CA (17 ± 4 mm) and CH (15 ± 3 mm) patients than in control patients (10 ± 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 ± 0.12) and ECV (0.56 ± 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 ± 0.07 and 0.36 ± 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 ± 0.07 and 0.35 ± 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters. • Dual-energy computed tomography can be used to detect cardiac amyloidosis • Five-minute myocardial iodine concentration and iodine ratio increase in cardiac amyloidosis • Among iodine parameters, 5-minute iodine ratio has the best diagnosis performance.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 33 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 33 100%

Demographic breakdown

Readers by professional status Count As %
Other 5 15%
Student > Ph. D. Student 4 12%
Student > Bachelor 4 12%
Student > Doctoral Student 3 9%
Student > Postgraduate 3 9%
Other 8 24%
Unknown 6 18%
Readers by discipline Count As %
Medicine and Dentistry 15 45%
Social Sciences 2 6%
Arts and Humanities 1 3%
Nursing and Health Professions 1 3%
Unspecified 1 3%
Other 2 6%
Unknown 11 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 August 2017.
All research outputs
#15,475,586
of 22,997,544 outputs
Outputs from European Radiology
#2,478
of 4,167 outputs
Outputs of similar age
#199,457
of 318,011 outputs
Outputs of similar age from European Radiology
#38
of 62 outputs
Altmetric has tracked 22,997,544 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 4,167 research outputs from this source. They receive a mean Attention Score of 4.6. This one is in the 31st percentile – i.e., 31% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 318,011 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 28th percentile – i.e., 28% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 62 others from the same source and published within six weeks on either side of this one. This one is in the 25th percentile – i.e., 25% of its contemporaries scored the same or lower than it.