↓ Skip to main content

Ergebnisse des deutschen Schulter- und Ellenbogenprothesenregisters (SEPR)

Overview of attention for article published in Die Orthopädie, October 2017
Altmetric Badge

Mentioned by

facebook
1 Facebook page

Citations

dimensions_citation
13 Dimensions
Title
Ergebnisse des deutschen Schulter- und Ellenbogenprothesenregisters (SEPR)
Published in
Die Orthopädie, October 2017
DOI 10.1007/s00132-017-3485-4
Pubmed ID
Authors

P. Magosch, P. Habermeyer, S. Lichtenberg, M. Tauber, F. Gohlke, F. Mauch, D. Boehm, M. Loew, F. Zeifang, W. Pötzl

Abstract

Anatomic shoulder arthroplasty in osteoarthritis with biconcave glenoid wear results in decreased functional results and a higher rate of early glenoid loosening. The aim of the data analysis of the German shoulder arthroplasty register was to clarify whether reverse shoulder arthroplasty can provide better functional results and a lower complication rate than anatomic arthroplasty in osteoarthritis with biconcave glenoid wear. The analysis included 1052 completely documented primary implanted arthroplasties with a minimum follow-up of 2 years. In 119 cases, a B2-type glenoid was present. Out of these cases, 86 were treated with an anatomic shoulder arthroplasty, and in 33 cases a reverse shoulder arthroplasty was implanted. The mean follow-up was 47.6 months. The Constant score with its subcategories, as well as the active range of movement improved significantly after anatomic and after reverse shoulder arthroplasty. We observed no difference in functional results between both types of arthroplasty; however, reverse arthroplasty showed a significant higher revision rate (21.2%) (3% glenoid loosening, 6% prosthetic instability) than anatomic shoulder arthroplasty (12.8%) (11.6% glenoid loosening, 1.2% prosthetic instability), whereas anatomic shoulder arthroplasty showed a higher rate of glenoid loosening. Functional and radiographic results of both types of arthroplasty are comparable with the results reported in the literature, although our analysis represents results from an implant registry (data pertaining to medical care quality).

Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 October 2017.
All research outputs
#22,764,772
of 25,382,440 outputs
Outputs from Die Orthopädie
#276
of 678 outputs
Outputs of similar age
#297,102
of 338,242 outputs
Outputs of similar age from Die Orthopädie
#3
of 32 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 678 research outputs from this source. They receive a mean Attention Score of 1.5. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 338,242 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 32 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.