↓ Skip to main content

EANM/EARL FDG-PET/CT accreditation - summary results from the first 200 accredited imaging systems

Overview of attention for article published in European Journal of Nuclear Medicine and Molecular Imaging, December 2017
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (71st percentile)
  • Good Attention Score compared to outputs of the same age and source (74th percentile)

Mentioned by

twitter
3 X users
wikipedia
1 Wikipedia page

Citations

dimensions_citation
110 Dimensions

Readers on

mendeley
103 Mendeley
Title
EANM/EARL FDG-PET/CT accreditation - summary results from the first 200 accredited imaging systems
Published in
European Journal of Nuclear Medicine and Molecular Imaging, December 2017
DOI 10.1007/s00259-017-3853-7
Pubmed ID
Authors

Andres Kaalep, Terez Sera, Wim Oyen, Bernd J. Krause, Arturo Chiti, Yan Liu, Ronald Boellaard

Abstract

From 2010 until July 2016, the EANM Research Ltd. (EARL) FDG-PET/CT accreditation program has collected over 2500 phantom datasets from approximately 200 systems and 150 imaging sites worldwide. The objective of this study is to report the findings and impact of the accreditation program on the participating PET/CT systems. To obtain and maintain EARL accredited status, sites were required to complete and submit two phantom scans - calibration quality control (CalQC), using a uniform cylindrical phantom and image quality control (IQQC), using a NEMA NU2-2007 body phantom. Average volumetric SUV bias and SUV recovery coefficients (RC) were calculated and the data evaluated on the basis of quality control (QC) type, approval status, PET/CT system manufacturer and submission order. SUV bias in 5% (n = 96) of all CalQC submissions (n = 1816) exceeded 10%. After corrective actions following EARL feedback, sites achieved 100% compliance within EARL specifications. 30% (n = 1381) of SUVmean and 23% (n = 1095) of SUVmax sphere recoveries from IQQC submissions failed to meet EARL accreditation criteria while after accreditation, failure rate decreased to 12% (n = 360) and 9% (n = 254), respectively. Most systems demonstrated longitudinal SUV bias reproducibility within ±5%, while RC values remained stable and generally within ±10% for the four largest and ±20% for the two smallest spheres. Regardless of manufacturer or model, all investigated systems are able to comply with the EARL specifications. Within the EARL accreditation program, gross PET/CT calibration errors are successfully identified and longitudinal variability in PET/CT performances reduced. The program demonstrates that a harmonising accreditation procedure is feasible and achievable.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 103 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 103 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 20 19%
Researcher 17 17%
Student > Master 15 15%
Other 9 9%
Student > Bachelor 6 6%
Other 10 10%
Unknown 26 25%
Readers by discipline Count As %
Medicine and Dentistry 39 38%
Physics and Astronomy 12 12%
Engineering 4 4%
Nursing and Health Professions 3 3%
Social Sciences 3 3%
Other 7 7%
Unknown 35 34%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 27 May 2023.
All research outputs
#7,238,286
of 25,837,817 outputs
Outputs from European Journal of Nuclear Medicine and Molecular Imaging
#945
of 3,565 outputs
Outputs of similar age
#128,910
of 448,913 outputs
Outputs of similar age from European Journal of Nuclear Medicine and Molecular Imaging
#10
of 39 outputs
Altmetric has tracked 25,837,817 research outputs across all sources so far. This one has received more attention than most of these and is in the 72nd percentile.
So far Altmetric has tracked 3,565 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 6.4. This one has gotten more attention than average, scoring higher than 73% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 448,913 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 71% of its contemporaries.
We're also able to compare this research output to 39 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 74% of its contemporaries.