Basic concepts in metal work failure after metastatic spine tumour surgery

Overview of attention for article published in European Spine Journal, December 2017
Altmetric Badge

Citations

dimensions_citation
18 Dimensions

Readers on

mendeley
25 Mendeley
Title
Basic concepts in metal work failure after metastatic spine tumour surgery
Published in
European Spine Journal, December 2017
DOI 10.1007/s00586-017-5405-z
Pubmed ID
Authors

Naresh Kumar, Ravish Patel, Anshuja Charvi Wadhwa, Aravind Kumar, Helena Maria Milavec, Dhiraj Sonawane, Gurpal Singh, Lorin Michael Benneker

Abstract

The development of spinal implants marks a watershed in the evolution of metastatic spine tumour surgery (MSTS), which has evolved from standalone decompressive laminectomy to instrumented stabilization and decompression with reconstruction when necessary. Fusion may not be feasible after MSTS due to poor quality of graft host bed along with adjunct chemotherapy and/or radiotherapy postoperatively. With an increase in the survival of patients with spinal tumours, there is a probability of an increase in the rate of implant failure. This review aims to help establish a clear understanding of implants/constructs used in MSTS and to highlight the fundamental biomechanics of implant/construct failures. Published literature on implant failure after spine surgery and MSTS has been reviewed. The evolution of spinal implants and their role in MSTS has been briefly described. The review defines implant/construct failures using radiological parameters that are practical, feasible, and derived from historical descriptions. We have discussed common modes of implant/construct failure after MSTS to allow further understanding, interception, and prevention of catastrophic failure. Implant failure rates in MSTS are in the range of 2-8%. Variability in patterns of failure has been observed based on anatomical region and the type of constructs used. Patients with construct/implant failures may or may not be symptomatic and present either as early (< 3months) or late failures (> 3months). It has been noted that not all the implant failures after MSTS result in revisions. Based on the observed radiological criteria and clinical presentations, we have proposed a clinico-radiological classification for implant/construct failure after MSTS.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 25 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 25 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 4 16%
Student > Postgraduate 3 12%
Professor > Associate Professor 3 12%
Student > Master 3 12%
Student > Bachelor 2 8%
Other 5 20%
Unknown 5 20%
Readers by discipline Count As %
Medicine and Dentistry 16 64%
Neuroscience 1 4%
Unknown 8 32%