Performance of combined fragmentation and retention prediction for the identification of organic micropollutants by LC-HRMS

Overview of attention for article published in Analytical & Bioanalytical Chemistry, January 2018
Altmetric Badge

About this Attention Score

  • Above-average Attention Score compared to outputs of the same age (51st percentile)
  • Good Attention Score compared to outputs of the same age and source (77th percentile)

Mentioned by

twitter
7 X users

Citations

dimensions_citation
23 Dimensions

Readers on

mendeley
50 Mendeley
Title
Performance of combined fragmentation and retention prediction for the identification of organic micropollutants by LC-HRMS
Published in
Analytical & Bioanalytical Chemistry, January 2018
DOI 10.1007/s00216-018-0857-5
Pubmed ID
Authors

Meng Hu, Erik Müller, Emma L. Schymanski, Christoph Ruttkies, Tobias Schulze, Werner Brack, Martin Krauss

Abstract

In nontarget screening, structure elucidation of small molecules from high resolution mass spectrometry (HRMS) data is challenging, particularly the selection of the most likely candidate structure among the many retrieved from compound databases. Several fragmentation and retention prediction methods have been developed to improve this candidate selection. In order to evaluate their performance, we compared two in silico fragmenters (MetFrag and CFM-ID) and two retention time prediction models (based on the chromatographic hydrophobicity index (CHI) and on log D). A set of 78 known organic micropollutants was analyzed by liquid chromatography coupled to a LTQ Orbitrap HRMS with electrospray ionization (ESI) in positive and negative mode using two fragmentation techniques with different collision energies. Both fragmenters (MetFrag and CFM-ID) performed well for most compounds, with average ranking the correct candidate structure within the top 25% and 22 to 37% for ESI+ and ESI- mode, respectively. The rank of the correct candidate structure slightly improved when MetFrag and CFM-ID were combined. For unknown compounds detected in both ESI+ and ESI-, generally positive mode mass spectra were better for further structure elucidation. Both retention prediction models performed reasonably well for more hydrophobic compounds but not for early eluting hydrophilic substances. The log D prediction showed a better accuracy than the CHI model. Although the two fragmentation prediction methods are more diagnostic and sensitive for candidate selection, the inclusion of retention prediction by calculating a consensus score with optimized weighting can improve the ranking of correct candidates as compared to the individual methods. Graphical abstract Consensus workflow for combining fragmentation and retention prediction in LC-HRMS-based micropollutant identification.

X Demographics

X Demographics

The data shown below were collected from the profiles of 7 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 50 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 50 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 13 26%
Researcher 9 18%
Student > Master 6 12%
Student > Doctoral Student 3 6%
Student > Postgraduate 3 6%
Other 9 18%
Unknown 7 14%
Readers by discipline Count As %
Chemistry 15 30%
Environmental Science 8 16%
Biochemistry, Genetics and Molecular Biology 4 8%
Agricultural and Biological Sciences 3 6%
Pharmacology, Toxicology and Pharmaceutical Science 3 6%
Other 6 12%
Unknown 11 22%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 12 March 2018.
All research outputs
#14,393,794
of 25,382,440 outputs
Outputs from Analytical & Bioanalytical Chemistry
#4,278
of 9,619 outputs
Outputs of similar age
#217,753
of 449,219 outputs
Outputs of similar age from Analytical & Bioanalytical Chemistry
#43
of 197 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one is in the 42nd percentile – i.e., 42% of other outputs scored the same or lower than it.
So far Altmetric has tracked 9,619 research outputs from this source. They receive a mean Attention Score of 3.1. This one has gotten more attention than average, scoring higher than 55% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 449,219 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 51% of its contemporaries.
We're also able to compare this research output to 197 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 77% of its contemporaries.