↓ Skip to main content

Comparative assessment of pharmacokinetics, and pharmacodynamics between RTXM83™, a rituximab biosimilar, and rituximab in diffuse large B-cell lymphoma patients: a population PK model approach

Overview of attention for article published in Cancer Chemotherapy and Pharmacology, January 2018
Altmetric Badge

Citations

dimensions_citation
31 Dimensions

Readers on

mendeley
38 Mendeley
Title
Comparative assessment of pharmacokinetics, and pharmacodynamics between RTXM83™, a rituximab biosimilar, and rituximab in diffuse large B-cell lymphoma patients: a population PK model approach
Published in
Cancer Chemotherapy and Pharmacology, January 2018
DOI 10.1007/s00280-018-3524-9
Pubmed ID
Authors

Myrna Candelaria, Derlis Gonzalez, Francisco Javier Fernández Gómez, Alexandra Paravisini, Ana Del Campo García, Luis Pérez, Bernardo Miguel-Lillo, Susana Millán

Abstract

The main objective was to quantify any potential differences in pharmacokinetic (PK) parameters (AUC and Cmax) between RTXM83, a proposed rituximab biosimilar, and its reference product, using a population PK model approach. Rituximab PK and PD data were obtained from a randomized, double-blind, phase III clinical study (RTXM83-AC-01-11) in patients with diffuse large B-cell lymphoma (DLBCL) that received 375 mg/m2 intravenous RTXM83 or its reference product with CHOP regimen, every 3 weeks, for six cycles. Rituximab levels were quantified by Meso Scale Discovery assay. PK analysis was performed using NONMEM 7.3.0. The effect of disease and patient covariates on RXTM83 PK was investigated. Model was evaluated using visual predictive check and non-parametric bootstrap. In total, 251 DLBCL patients (127 and 124 in RXTM83-CHOP and rituximab-CHOP arms, respectively) and 5341 serum concentrations (2703 for RXTM83 and 2638 for rituximab, respectively) were available for the population PK analysis. The volume of distribution of the central compartment (V1) and clearance of RXTM83 were estimated at 3.19 L and 12.5 mL/h, respectively. Body surface area allowed to explain the interindividual variability for V1. A statistical analysis showed that systemic exposure (AUC and Cmax) of RTXM83 was similar to rituximab. The 90% confidence intervals for all pairwise comparisons were within the predefined bioequivalence interval of 0.80-1.25. PD similarity of B-cell depletion and recovery was also observed. The time course of RTXM83 was well characterized by the model developed. The systemic exposure of RTXM83 and its associated variability were similar to those for rituximab reference in DLBCL patients, demonstrating PK similarity. The PD similarity of RTXM83 and rituximab reference product was also demonstrated.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 38 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 38 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 8 21%
Researcher 7 18%
Student > Ph. D. Student 5 13%
Other 3 8%
Student > Doctoral Student 3 8%
Other 4 11%
Unknown 8 21%
Readers by discipline Count As %
Pharmacology, Toxicology and Pharmaceutical Science 12 32%
Medicine and Dentistry 4 11%
Biochemistry, Genetics and Molecular Biology 3 8%
Immunology and Microbiology 3 8%
Nursing and Health Professions 2 5%
Other 3 8%
Unknown 11 29%