↓ Skip to main content

Characterizing left ventricular mechanical and electrical activation in patients with normal and impaired systolic function using a non-fluoroscopic cardiovascular navigation system

Overview of attention for article published in Journal of Interventional Cardiac Electrophysiology, January 2018
Altmetric Badge

Mentioned by

twitter
2 X users
facebook
2 Facebook pages

Citations

dimensions_citation
1 Dimensions

Readers on

mendeley
22 Mendeley
Title
Characterizing left ventricular mechanical and electrical activation in patients with normal and impaired systolic function using a non-fluoroscopic cardiovascular navigation system
Published in
Journal of Interventional Cardiac Electrophysiology, January 2018
DOI 10.1007/s10840-018-0317-3
Pubmed ID
Authors

Christopher Piorkowski, Arash Arya, Craig D. Markovitz, Hedi Razavi, Chunlan Jiang, Stuart Rosenberg, Ole-A. Breithardt, Sascha Rolf, Silke John, Jedrzej Kosiuk, Yan Huo, Michael Döring, Sergio Richter, Kyungmoo Ryu, Thomas Gaspar, Frits W. Prinzen, Gerhard Hindricks, Philipp Sommer

Abstract

Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF). NSF (n = 10; ejection fraction = 62.9 ± 6.1%) and ISF (n = 18; ejection fraction = 35.1 ± 13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls. NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients. This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy. URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 22 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 22 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 6 27%
Researcher 3 14%
Student > Bachelor 2 9%
Student > Postgraduate 2 9%
Professor 1 5%
Other 2 9%
Unknown 6 27%
Readers by discipline Count As %
Medicine and Dentistry 9 41%
Engineering 3 14%
Neuroscience 2 9%
Materials Science 1 5%
Unknown 7 32%