↓ Skip to main content

Can bioprosthetic valve thrombosis be promoted by aortic root morphology? An in vitro study†

Overview of attention for article published in Interactive Cardiovascular and Thoracic Surgery, February 2018
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (65th percentile)
  • High Attention Score compared to outputs of the same age and source (86th percentile)

Mentioned by

twitter
5 X users

Citations

dimensions_citation
14 Dimensions

Readers on

mendeley
28 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Can bioprosthetic valve thrombosis be promoted by aortic root morphology? An in vitro study†
Published in
Interactive Cardiovascular and Thoracic Surgery, February 2018
DOI 10.1093/icvts/ivy039
Pubmed ID
Authors

Silje Ekroll Jahren, Paul Philipp Heinisch, David Hasler, Bernhard Michael Winkler, Stefan Stortecky, Thomas Pilgrim, Martina Correa Londono, Thierry Carrel, Hendrik von Tengg-Kobligk, Dominik Obrist

Abstract

Bioprosthetic valve thrombosis has been considered uncommon, but recent studies have shown that it is more frequent than previously thought. Insufficient washout of the aortic sinus is believed to be a risk factor for bioprosthetic valve thrombosis. The objective of this in vitro experiment was to investigate the impact of aortic root morphology on blood flow in the aortic sinus and to relate these results to in vivo data obtained in patients with a transcatheter aortic valve implant. Two compliant aortic root phantoms with different morphologies (symmetrical and patient-specific) were fabricated with silicone. A bioprosthetic aortic valve was inserted in both phantoms. Haemodynamic measurements were performed in a pulsatile flow-loop replicating physiological flow and pressure conditions. The flow in the aortic root was visualized by injecting contrast agent (CA). The distribution of the CA was captured by a high-speed camera, and image post-processing was performed to quantify CA distribution in the aortic sinus. The results were compared with angiographic images after a transcatheter aortic valve implant. Blood flow in the aortic root and the washout of the sinus portion are significantly affected by aortic root morphology. CA arrives at the aortic sinus of the 2 phantoms at 0.09 s and 0.16 s after the valve opens in the symmetrical and the patient-specific phantoms, respectively. Delayed CA arrival was also observed in the patients with a transcatheter aortic valve implant. Aortic root morphology affects the blood flow in the aortic sinus and may be a factor in bioprosthetic valve thrombosis. Therefore, patient-specific aortic root morphology should be considered when selecting and positioning a prosthesis.

X Demographics

X Demographics

The data shown below were collected from the profiles of 5 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 28 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 28 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 4 14%
Student > Ph. D. Student 3 11%
Student > Bachelor 2 7%
Professor 2 7%
Student > Doctoral Student 2 7%
Other 7 25%
Unknown 8 29%
Readers by discipline Count As %
Engineering 9 32%
Medicine and Dentistry 7 25%
Materials Science 2 7%
Unknown 10 36%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 01 March 2018.
All research outputs
#7,141,451
of 25,382,440 outputs
Outputs from Interactive Cardiovascular and Thoracic Surgery
#274
of 2,330 outputs
Outputs of similar age
#117,250
of 344,362 outputs
Outputs of similar age from Interactive Cardiovascular and Thoracic Surgery
#6
of 44 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one has received more attention than most of these and is in the 71st percentile.
So far Altmetric has tracked 2,330 research outputs from this source. They receive a mean Attention Score of 2.6. This one has done well, scoring higher than 88% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 344,362 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 65% of its contemporaries.
We're also able to compare this research output to 44 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 86% of its contemporaries.