↓ Skip to main content

Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters

Overview of attention for article published in Journal of Interventional Cardiac Electrophysiology, February 2018
Altmetric Badge

Mentioned by

news
11 news outlets
twitter
37 X users

Citations

dimensions_citation
92 Dimensions

Readers on

mendeley
58 Mendeley
Title
Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters
Published in
Journal of Interventional Cardiac Electrophysiology, February 2018
DOI 10.1007/s10840-018-0322-6
Pubmed ID
Authors

Roger A. Winkle, Ryan Moskovitz, R. Hardwin Mead, Gregory Engel, Melissa H. Kong, William Fleming, Jonathan Salcedo, Rob A. Patrawala, John H. Tranter, Isaac Shai

Abstract

The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.

X Demographics

X Demographics

The data shown below were collected from the profiles of 37 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 58 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 58 100%

Demographic breakdown

Readers by professional status Count As %
Other 10 17%
Researcher 10 17%
Student > Doctoral Student 6 10%
Student > Postgraduate 5 9%
Student > Bachelor 4 7%
Other 6 10%
Unknown 17 29%
Readers by discipline Count As %
Medicine and Dentistry 22 38%
Engineering 3 5%
Agricultural and Biological Sciences 2 3%
Nursing and Health Professions 2 3%
Pharmacology, Toxicology and Pharmaceutical Science 1 2%
Other 7 12%
Unknown 21 36%