↓ Skip to main content

Development of 3D printed fibrillar collagen scaffold for tissue engineering

Overview of attention for article published in Biomedical Microdevices, February 2018
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (67th percentile)
  • Good Attention Score compared to outputs of the same age and source (66th percentile)

Mentioned by

twitter
4 X users
patent
1 patent

Citations

dimensions_citation
99 Dimensions

Readers on

mendeley
223 Mendeley
Title
Development of 3D printed fibrillar collagen scaffold for tissue engineering
Published in
Biomedical Microdevices, February 2018
DOI 10.1007/s10544-018-0270-z
Pubmed ID
Authors

Aden Díaz Nocera, Romina Comín, Nancy Alicia Salvatierra, Mariana Paula Cid

Abstract

Collagen is widely used in tissue engineering because it can be extracted in large quantities, and has excellent biocompatibility, good biodegradability, and weak antigenicity. In the present study, we isolated printable collagen from bovine Achilles tendon and examined the purity of the isolated collagen using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The bands obtained corresponded to α1, α2and β chains with little contamination from other small proteins. Furthermore, rheological measurements of collagen dispersions (60 mg per ml of PBS) at pH 7 revealed values of viscosity of 35.62 ± 1.42 Pa s at shear rate of 10 s - 1 and a shear thinning behavior. Collagen gels and solutions can be used for building scaffolds by three-dimensional (3D) printing. After designing and fabricating a low-cost 3D printer we assayed the collagen printing and obtaining 3D printed scaffolds of collagen at pH 7. The porosity of the scaffold was 90.22% ± 0.88% and the swelling ratio was 1437% ± 146%. The microstructure of the scaffolds was studied using scanning electron microscopy, and a porous mesh of fibrillar collagen was observed. In addition, the 3D printed collagen scaffold was not cytotoxic with cell viability higher than 70% using Vero and NIH 3 T3 cells. In vitro evaluation using both cells lines demonstrated that the collagen scaffolds had the ability to support cell attachment and proliferation. Also a fibrillar collagen mesh was observed after two weeks of culture at 37 °C. Overall, these results are promising since they show the capability of the presented protocol to obtain printable fibrillar collagen at pH 7 and the potential of the printing technique for building low-cost biocompatible 3D plotted structures which maintained the fibrillar collagen structure after incubation in culture media without using additional strategies as crosslinking.

X Demographics

X Demographics

The data shown below were collected from the profiles of 4 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 223 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 223 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 45 20%
Student > Ph. D. Student 39 17%
Student > Bachelor 27 12%
Researcher 22 10%
Student > Doctoral Student 17 8%
Other 23 10%
Unknown 50 22%
Readers by discipline Count As %
Engineering 35 16%
Biochemistry, Genetics and Molecular Biology 33 15%
Materials Science 33 15%
Medicine and Dentistry 14 6%
Agricultural and Biological Sciences 11 5%
Other 35 16%
Unknown 62 28%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 27 September 2023.
All research outputs
#6,507,991
of 24,654,416 outputs
Outputs from Biomedical Microdevices
#212
of 777 outputs
Outputs of similar age
#106,778
of 334,795 outputs
Outputs of similar age from Biomedical Microdevices
#3
of 6 outputs
Altmetric has tracked 24,654,416 research outputs across all sources so far. This one has received more attention than most of these and is in the 73rd percentile.
So far Altmetric has tracked 777 research outputs from this source. They receive a mean Attention Score of 4.2. This one has gotten more attention than average, scoring higher than 72% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 334,795 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 67% of its contemporaries.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one. This one has scored higher than 3 of them.