↓ Skip to main content

High bacterial contamination rate of electrocautery tips during total hip and knee arthroplasty

Overview of attention for article published in International Orthopaedics, February 2018
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (78th percentile)
  • High Attention Score compared to outputs of the same age and source (81st percentile)

Mentioned by

news
1 news outlet
facebook
1 Facebook page

Citations

dimensions_citation
14 Dimensions

Readers on

mendeley
26 Mendeley
Title
High bacterial contamination rate of electrocautery tips during total hip and knee arthroplasty
Published in
International Orthopaedics, February 2018
DOI 10.1007/s00264-018-3822-1
Pubmed ID
Authors

Hussein Abdelaziz, Akos Zahar, Christian Lausmann, Thorsten Gehrke, Helmut Fickenscher, Eduardo M. Suero, Matthias Gebauer, Mustafa Citak

Abstract

The aim of the study was to quantify the bacterial contamination rate of electrocautery tips during primary total joint replacement (TJR), as well as during aseptic and septic revision TJR. A total of 150 electrocautery tips were collected between April and July 2017. TJR surgeries were divided into three groups: (1) primary, (2) aseptic and (3) septic revisions. In each group, a total of 50 electrocautery tips were collected. A monopolar electrocautery with a reusable stainless-steel blade tip was used in all cases. The rate of bacterial contamination was determined for all groups. Correlation of exposure time and type of surgery was analyzed. The overall bacterial contamination rate was 14.7% (95% CI 9.4 to 21.4%). The highest contamination rate occurred in the septic revision group (30.0%; 95% CI 17.9 to 44.6%), followed by the primary cases group (10.0%; 95% CI 3.3 to 21.8%) and the aseptic revision group (4.0%; 95% CI 0.5 to 13.7%). Exposure time did not affect the bacterial contamination rate. In 12 out of 15 (80%) contaminations identified in the septic group, we found the same causative microorganism of the prosthetic joint infection on the electrocautery tip. The bacterial contamination of the electrocautery tips is relatively high, especially during septic hip revision arthroplasty. Electrocautery tips should be changed after debridement of infected tissue.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 26 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 26 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 4 15%
Student > Bachelor 3 12%
Student > Doctoral Student 2 8%
Researcher 2 8%
Student > Ph. D. Student 2 8%
Other 3 12%
Unknown 10 38%
Readers by discipline Count As %
Medicine and Dentistry 11 42%
Nursing and Health Professions 1 4%
Engineering 1 4%
Unknown 13 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 8. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 October 2022.
All research outputs
#4,289,235
of 23,504,694 outputs
Outputs from International Orthopaedics
#154
of 1,478 outputs
Outputs of similar age
#96,429
of 447,582 outputs
Outputs of similar age from International Orthopaedics
#6
of 33 outputs
Altmetric has tracked 23,504,694 research outputs across all sources so far. Compared to these this one has done well and is in the 81st percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 1,478 research outputs from this source. They receive a mean Attention Score of 4.4. This one has done well, scoring higher than 89% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 447,582 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 78% of its contemporaries.
We're also able to compare this research output to 33 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 81% of its contemporaries.