↓ Skip to main content

Design and fabrication of an artificial cornea based on a photolithographically patterned hydrogel construct

Overview of attention for article published in Biomedical Microdevices, January 2007
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (80th percentile)
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

patent
5 patents

Citations

dimensions_citation
103 Dimensions

Readers on

mendeley
96 Mendeley
Title
Design and fabrication of an artificial cornea based on a photolithographically patterned hydrogel construct
Published in
Biomedical Microdevices, January 2007
DOI 10.1007/s10544-006-9040-4
Pubmed ID
Authors

David Myung, Wongun Koh, Amit Bakri, Fan Zhang, Amanda Marshall, Jungmin Ko, Jaan Noolandi, Michael Carrasco, Jennifer R. Cochran, Curtis W. Frank, Christopher N. Ta

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 96 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Hungary 1 1%
Korea, Republic of 1 1%
United Kingdom 1 1%
Iran, Islamic Republic of 1 1%
Czechia 1 1%
United States 1 1%
Unknown 90 94%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 34 35%
Researcher 18 19%
Student > Bachelor 9 9%
Student > Doctoral Student 7 7%
Student > Master 7 7%
Other 14 15%
Unknown 7 7%
Readers by discipline Count As %
Engineering 27 28%
Chemistry 15 16%
Agricultural and Biological Sciences 15 16%
Materials Science 11 11%
Medicine and Dentistry 9 9%
Other 10 10%
Unknown 9 9%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 6. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 01 January 2019.
All research outputs
#4,759,510
of 23,033,713 outputs
Outputs from Biomedical Microdevices
#99
of 755 outputs
Outputs of similar age
#22,026
of 160,589 outputs
Outputs of similar age from Biomedical Microdevices
#6
of 18 outputs
Altmetric has tracked 23,033,713 research outputs across all sources so far. Compared to these this one has done well and is in the 76th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 755 research outputs from this source. They receive a mean Attention Score of 4.1. This one has gotten more attention than average, scoring higher than 74% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 160,589 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 80% of its contemporaries.
We're also able to compare this research output to 18 others from the same source and published within six weeks on either side of this one. This one is in the 33rd percentile – i.e., 33% of its contemporaries scored the same or lower than it.