↓ Skip to main content

Fluorescence-Based Blood Coagulation Assay Device for Measuring Activated Partial Thromboplastin Time

Overview of attention for article published in Analytical Chemistry, December 2010
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
13 Dimensions

Readers on

mendeley
52 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Fluorescence-Based Blood Coagulation Assay Device for Measuring Activated Partial Thromboplastin Time
Published in
Analytical Chemistry, December 2010
DOI 10.1021/ac102436v
Pubmed ID
Authors

Magdalena M. Dudek, Nigel Kent, Kerstin M. Gustafsson, Tomas L. Lindahl, Anthony J. Killard

Abstract

The measurement of blood clotting time is important in a range of clinical applications such as assessing coagulation disorders and controlling the effect of various anticoagulant drug therapies. Clotting time tests essentially measure the onset of clot formation which results from the formation of fibrin fibers in the blood sample. However, such assays are inherently imprecise due to the highly variable nature of the clot formation process and the sample matrix. This work describes a clotting time measurement assay which uses a fluorescent probe to very precisely detect the onset of fibrin clot formation. It uses a microstructured surface which enhances the formation of multiple localized clot loci and which results in the abrupt redistribution of the fluorescent label at the onset of clot formation in both whole blood and plasma. This methodology was applied to the development of an activated partial thromboplastin time (aPTT) test in a lateral flow microfluidic platform and used to monitor the effect of heparin dosage where it showed linearity from 0 to 2 U/mL in spiked plasma samples (R(2)=0.996, n = 3), correlation against gold standard coagulometry of 0.9986, and correlation against standard hospital aPTT in 32 patient samples of 0.78.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 52 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Netherlands 1 2%
Ireland 1 2%
Germany 1 2%
Unknown 49 94%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 16 31%
Researcher 8 15%
Student > Bachelor 7 13%
Student > Doctoral Student 6 12%
Lecturer 3 6%
Other 6 12%
Unknown 6 12%
Readers by discipline Count As %
Engineering 17 33%
Agricultural and Biological Sciences 6 12%
Nursing and Health Professions 5 10%
Chemistry 4 8%
Immunology and Microbiology 2 4%
Other 9 17%
Unknown 9 17%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 16 February 2015.
All research outputs
#20,262,276
of 22,792,160 outputs
Outputs from Analytical Chemistry
#24,292
of 26,445 outputs
Outputs of similar age
#170,207
of 180,517 outputs
Outputs of similar age from Analytical Chemistry
#115
of 117 outputs
Altmetric has tracked 22,792,160 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 26,445 research outputs from this source. They receive a mean Attention Score of 4.7. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 180,517 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 117 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.