↓ Skip to main content

Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting

Overview of attention for article published in BMC Cardiovascular Disorders, March 2018
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (81st percentile)
  • High Attention Score compared to outputs of the same age and source (85th percentile)

Mentioned by

news
1 news outlet
twitter
2 X users

Citations

dimensions_citation
20 Dimensions

Readers on

mendeley
45 Mendeley
Title
Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting
Published in
BMC Cardiovascular Disorders, March 2018
DOI 10.1186/s12872-018-0790-8
Pubmed ID
Authors

Susanne Röger, Stefanie L. Rosenkaimer, Anna Hohneck, Siegfried Lang, Ibrahim El-Battrawy, Boris Rudic, Erol Tülümen, Ksenija Stach, Jürgen Kuschyk, Ibrahim Akin, Martin Borggrefe

Abstract

The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 45 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 45 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 8 18%
Other 8 18%
Student > Master 8 18%
Student > Ph. D. Student 3 7%
Student > Bachelor 3 7%
Other 5 11%
Unknown 10 22%
Readers by discipline Count As %
Medicine and Dentistry 20 44%
Nursing and Health Professions 3 7%
Pharmacology, Toxicology and Pharmaceutical Science 2 4%
Biochemistry, Genetics and Molecular Biology 1 2%
Agricultural and Biological Sciences 1 2%
Other 7 16%
Unknown 11 24%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 11. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 05 November 2020.
All research outputs
#2,855,983
of 23,043,346 outputs
Outputs from BMC Cardiovascular Disorders
#109
of 1,639 outputs
Outputs of similar age
#62,070
of 333,789 outputs
Outputs of similar age from BMC Cardiovascular Disorders
#4
of 28 outputs
Altmetric has tracked 23,043,346 research outputs across all sources so far. Compared to these this one has done well and is in the 87th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 1,639 research outputs from this source. They receive a mean Attention Score of 3.9. This one has done particularly well, scoring higher than 93% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 333,789 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 81% of its contemporaries.
We're also able to compare this research output to 28 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 85% of its contemporaries.