Midwives’ perceptions on using a fetoscope and Doppler for fetal heart rate assessments during labor: a qualitative study in rural Tanzania

Overview of attention for article published in BMC Pregnancy and Childbirth, April 2018
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
2 X users
facebook
1 Facebook page

Citations

dimensions_citation
10 Dimensions

Readers on

mendeley
76 Mendeley
Title
Midwives’ perceptions on using a fetoscope and Doppler for fetal heart rate assessments during labor: a qualitative study in rural Tanzania
Published in
BMC Pregnancy and Childbirth, April 2018
DOI 10.1186/s12884-018-1736-y
Pubmed ID
Authors

Paschal Francis Mdoe, Hege Langli Ersdal, Estomih Mduma, Robert Moshiro, Hussein Kidanto, Columba Mbekenga

Abstract

The Doppler is thought to be more comfortable and effective compared to the fetoscope for assessing the fetal heart rate (FHR) during labor. However, in a rural Tanzanian hospital, midwives who had easy access to both devices mostly used fetoscope. This study explored midwives' perception of factors influencing their preference for using either a Pinard fetoscope or a FreePlay wind-up Doppler for intermittent FHR monitoring. Midwives who had worked for at least 6 months in the labor ward were recruited. Focus group discussion (FGD) was used to collect data. Five FGDs were conducted between December 2015 and February 2016. Qualitative content analysis was employed using NVivo 11.0. Three main themes emerged as factors perceived by midwives as influencing their preference; 1) Sufficient training and experience with using a device; Midwives had been using fetoscopes since their midwifery training, and they had vast experience using it. The Doppler was recently introduced in the maternity ward, and midwives had insufficient training in how to use it. 2) Ability of the device to produce reliable measurements; Using a fetoscope, one must listen for the heartbeat, count using a watch, and calculate, the Doppler provides both a display and sound of the FHR. Fetoscope measurements are prone to human errors, and Doppler measurements are prone to instrumental errors. 3) Convenience of use and comfort of a device; Fetoscopes do not need charging, and while it is possible to "personalize/hide" the measurements, and may be painful for mothers. Dopplers need charging and do not cause pain, but provide limited privacy. Midwives' preferences of FHR monitoring devices are influenced by the level of device training, experience with using a device, reliable measurements, and convenience and comfort during use. Fetoscopes and Dopplers should be equally available during midwifery training and in clinical practice.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 76 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 76 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 11 14%
Student > Ph. D. Student 9 12%
Researcher 7 9%
Student > Bachelor 7 9%
Librarian 4 5%
Other 14 18%
Unknown 24 32%
Readers by discipline Count As %
Medicine and Dentistry 17 22%
Nursing and Health Professions 13 17%
Social Sciences 4 5%
Engineering 3 4%
Psychology 3 4%
Other 8 11%
Unknown 28 37%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 November 2018.
All research outputs
#16,296,140
of 24,777,509 outputs
Outputs from BMC Pregnancy and Childbirth
#3,116
of 4,622 outputs
Outputs of similar age
#185,097
of 301,839 outputs
Outputs of similar age from BMC Pregnancy and Childbirth
#94
of 114 outputs
Altmetric has tracked 24,777,509 research outputs across all sources so far. This one is in the 32nd percentile – i.e., 32% of other outputs scored the same or lower than it.
So far Altmetric has tracked 4,622 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 9.2. This one is in the 29th percentile – i.e., 29% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 301,839 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 35th percentile – i.e., 35% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 114 others from the same source and published within six weeks on either side of this one. This one is in the 14th percentile – i.e., 14% of its contemporaries scored the same or lower than it.