↓ Skip to main content

American College of Cardiology

Novel PET and Near Infrared Imaging Probes for the Specific Detection of Bacterial Infections Associated With Cardiac Devices

Overview of attention for article published in JACC: Cardiovascular Imaging, April 2018
Altmetric Badge

About this Attention Score

  • In the top 5% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (93rd percentile)
  • High Attention Score compared to outputs of the same age and source (86th percentile)

Mentioned by

news
4 news outlets
blogs
1 blog
twitter
9 X users

Citations

dimensions_citation
35 Dimensions

Readers on

mendeley
32 Mendeley
Title
Novel PET and Near Infrared Imaging Probes for the Specific Detection of Bacterial Infections Associated With Cardiac Devices
Published in
JACC: Cardiovascular Imaging, April 2018
DOI 10.1016/j.jcmg.2018.02.011
Pubmed ID
Authors

Kiyoko Takemiya, Xinghai Ning, Wonewoo Seo, Xiaojian Wang, Rafi Mohammad, Giji Joseph, Jane S Titterington, Colleen S Kraft, Jonathan A Nye, Niren Murthy, Mark M Goodman, W Robert Taylor

Abstract

The aim of this study was to develop imaging agents to detect early stage infections in implantable cardiac devices. Bacteria ingest maltodextrins through the specific maltodextrin transporter. We developed probes conjugated with either a fluorescent dye (maltohexaose fluorescent dye probe [MDP]) or a F-18 (F18 fluoromaltohexaose) and determined their usefulness in a model of infections associated with implanted cardiac devices. Stainless steel mock-ups of medical devices were implanted subcutaneously in rats. On post-operative day 4, animals were injected with either Staphylococcus aureus around the mock-ups to induce a relatively mild infection or oil of turpentine to induce noninfectious inflammation. Animals with a sterile implant were used as control subjects. On post-operative day 6, either the MDP or F18 fluoromaltohexaose was injected intravenously, and the animals were scanned with the appropriate imaging device. Additional positron emission tomography imaging studies were performed with F18-fluorodeoxyglucose as a comparison of the specificity of our probes (n = 5 to 9 per group). The accumulation of the MDP in the infected rats was significantly increased at 1 h after injection when compared with the control and noninfectious inflammation groups (intensity ratio 1.54 ± 0.07 vs. 1.26 ± 0.04 and 1.20 ± 0.05, respectively; p < 0.05) and persisted for more than 24 h. In positron emission tomography imaging, both F18 fluoromaltohexaose and F18 fluorodeoxyglucose significantly accumulated in the infected area 30 min after the injection (maximum standard uptake value ratio 4.43 ± 0.30 and 4.87 ± 0.28, respectively). In control rats, there was no accumulation of imaging probes near the device. In the noninfectious inflammation rats, no significant accumulation was observed with F18 fluoromaltohexaose, but F18 fluorodeoxyglucose accumulated in the mock-up area (maximum standard uptake value 2.53 ± 0.39 vs. 4.74 ± 0.46, respectively; p < 0.05). Our results indicate that maltohexaose-based imaging probes are potentially useful for the specific and sensitive diagnosis of infections associated with implantable cardiac devices.

X Demographics

X Demographics

The data shown below were collected from the profiles of 9 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 32 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 32 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 6 19%
Student > Bachelor 4 13%
Student > Ph. D. Student 3 9%
Student > Postgraduate 2 6%
Student > Doctoral Student 2 6%
Other 7 22%
Unknown 8 25%
Readers by discipline Count As %
Medicine and Dentistry 9 28%
Chemistry 5 16%
Agricultural and Biological Sciences 4 13%
Unspecified 1 3%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Other 1 3%
Unknown 11 34%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 40. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 11 May 2019.
All research outputs
#1,026,300
of 25,382,440 outputs
Outputs from JACC: Cardiovascular Imaging
#302
of 2,700 outputs
Outputs of similar age
#22,676
of 340,784 outputs
Outputs of similar age from JACC: Cardiovascular Imaging
#8
of 61 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. Compared to these this one has done particularly well and is in the 95th percentile: it's in the top 5% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 2,700 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 18.1. This one has done well, scoring higher than 88% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 340,784 tracked outputs that were published within six weeks on either side of this one in any source. This one has done particularly well, scoring higher than 93% of its contemporaries.
We're also able to compare this research output to 61 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 86% of its contemporaries.