↓ Skip to main content

Dosimetric characterization of two radium sources for retrospective dosimetry studies

Overview of attention for article published in Medical Physics, November 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Above-average Attention Score compared to outputs of the same age and source (55th percentile)

Mentioned by

twitter
2 X users

Citations

dimensions_citation
3 Dimensions

Readers on

mendeley
8 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Dosimetric characterization of two radium sources for retrospective dosimetry studies
Published in
Medical Physics, November 2016
DOI 10.1118/1.4916685
Pubmed ID
Authors

C Candela-Juan, M Karlsson, M Lundell, F Ballester, Å Carlsson Tedgren

Abstract

During the first part of the 20th century, (226)Ra was the most used radionuclide for brachytherapy. Retrospective accurate dosimetry, coupled with patient follow up, is important for advancing knowledge on long-term radiation effects. The purpose of this work was to dosimetrically characterize two (226)Ra sources, commonly used in Sweden during the first half of the 20th century, for retrospective dose-effect studies. An 8 mg (226)Ra tube and a 10 mg (226)Ra needle, used at Radiumhemmet (Karolinska University Hospital, Stockholm, Sweden), from 1925 to the 1960s, were modeled in two independent Monte Carlo (MC) radiation transport codes: geant4 and mcnp5. Absorbed dose and collision kerma around the two sources were obtained, from which the TG-43 parameters were derived for the secular equilibrium state. Furthermore, results from this dosimetric formalism were compared with results from a MC simulation with a superficial mould constituted by five needles inside a glass casing, placed over a water phantom, trying to mimic a typical clinical setup. Calculated absorbed doses using the TG-43 formalism were also compared with previously reported measurements and calculations based on the Sievert integral. Finally, the dose rate at large distances from a (226)Ra point-like-source placed in the center of 1 m radius water sphere was calculated with geant4. TG-43 parameters [including gL(r), F(r, θ), Λ, and sK] have been uploaded in spreadsheets as additional material, and the fitting parameters of a mathematical curve that provides the dose rate between 10 and 60 cm from the source have been provided. Results from TG-43 formalism are consistent within the treatment volume with those of a MC simulation of a typical clinical scenario. Comparisons with reported measurements made with thermoluminescent dosimeters show differences up to 13% along the transverse axis of the radium needle. It has been estimated that the uncertainty associated to the absorbed dose within the treatment volume is 10%-15%, whereas uncertainty of absorbed dose to distant organs is roughly 20%-25%. The results provided here facilitate retrospective dosimetry studies of (226)Ra using modern treatment planning systems, which may be used to improve knowledge on long term radiation effects. It is surely important for the epidemiologic studies to be aware of the estimated uncertainty provided here before extracting their conclusions.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 8 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 8 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 2 25%
Professor 1 13%
Student > Bachelor 1 13%
Student > Doctoral Student 1 13%
Unknown 3 38%
Readers by discipline Count As %
Physics and Astronomy 2 25%
Environmental Science 1 13%
Chemical Engineering 1 13%
Unknown 4 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 10 April 2015.
All research outputs
#16,079,592
of 24,464,848 outputs
Outputs from Medical Physics
#5,070
of 7,873 outputs
Outputs of similar age
#248,092
of 425,144 outputs
Outputs of similar age from Medical Physics
#86
of 225 outputs
Altmetric has tracked 24,464,848 research outputs across all sources so far. This one is in the 32nd percentile – i.e., 32% of other outputs scored the same or lower than it.
So far Altmetric has tracked 7,873 research outputs from this source. They receive a mean Attention Score of 3.4. This one is in the 31st percentile – i.e., 31% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 425,144 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 38th percentile – i.e., 38% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 225 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 55% of its contemporaries.