↓ Skip to main content

Transpapillary endopancreatic surgery: decompression of duct system and comparison of greenlight laser with monopolar electrosurgical device in ex vivo and in vivo animal models

Overview of attention for article published in Surgical Endoscopy, May 2018
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Above-average Attention Score compared to outputs of the same age and source (61st percentile)

Mentioned by

twitter
5 X users

Citations

dimensions_citation
3 Dimensions

Readers on

mendeley
16 Mendeley
Title
Transpapillary endopancreatic surgery: decompression of duct system and comparison of greenlight laser with monopolar electrosurgical device in ex vivo and in vivo animal models
Published in
Surgical Endoscopy, May 2018
DOI 10.1007/s00464-018-6198-9
Pubmed ID
Authors

Philip C. Müller, Daniel C. Steinemann, Lukas Chinczewski, Gencay Hatiboglu, Felix Nickel, Kaspar Z’graggen, Beat P. Müller-Stich

Abstract

Endopancreatic surgery (EPS) is an experimental minimally invasive technique for resection of pancreatic tissue from inside the pancreatic duct, accessed via the duodenum and papilla. It is proposed as an alternative to duodenum-preserving pancreatic head resection in benign diseases such as chronic pancreatitis (CP). This study evaluated the use of EPS for resection of pancreatic duct stenoses. Moreover, greenlight laser (GLL) and monopolar electrosurgical device (MES) were compared as resection tools for EPS. The suitability of EPS for resection of stenoses was evaluated in ex vivo bovine pancreas (n = 8). Artificially created stenoses in the pancreatic head were accessed via the duodenal papilla and resected from inside the organ with MES through a rigid endoscope. Furthermore, standardized pancreatic resections were performed in an in vivo porcine model using either GLL (n = 18) or MES (n = 18) to compare blood loss, operating time, and complications. Thermal damage to the surrounding tissue was assessed using a standardized histological classification. Stenosis resection by EPS was feasible in 8/8 bovine pancreases, with a procedure time of 17 (12-24) min. No perforation of the organ occurred. Resection by GLL was associated with reduced blood loss [median 1.7 (interquartile range 0.6-2.6) ml vs. 5.1 (3.8-13.2) ml; p < 0.01] and shorter operating time [109 (81-127) s vs. 390 (337-555) s; p < 0.01] compared with MES. The zone of thermal tissue damage was more extensive when using GLL than with MES [4.12 (3.48-4.89) mm vs. 1.33 (1.09-1.48) mm; p < 0.01]. Transduodenal-transpapillary EPS can be used to resect stenoses and decompress the pancreatic duct system. Both GLL and MES are feasible resection methods for EPS. However, GLL showed better hemostatic characteristics than MES in an in vivo porcine model. Safety measures such as temperature control and image-guided navigation should be employed to monitor the resection and tissue heating.

X Demographics

X Demographics

The data shown below were collected from the profiles of 5 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 16 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 16 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 2 13%
Student > Ph. D. Student 2 13%
Lecturer 1 6%
Other 1 6%
Professor 1 6%
Other 3 19%
Unknown 6 38%
Readers by discipline Count As %
Medicine and Dentistry 5 31%
Nursing and Health Professions 2 13%
Computer Science 1 6%
Engineering 1 6%
Unknown 7 44%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 May 2018.
All research outputs
#13,240,449
of 23,045,021 outputs
Outputs from Surgical Endoscopy
#2,700
of 6,111 outputs
Outputs of similar age
#161,424
of 326,177 outputs
Outputs of similar age from Surgical Endoscopy
#37
of 100 outputs
Altmetric has tracked 23,045,021 research outputs across all sources so far. This one is in the 42nd percentile – i.e., 42% of other outputs scored the same or lower than it.
So far Altmetric has tracked 6,111 research outputs from this source. They receive a mean Attention Score of 4.1. This one has gotten more attention than average, scoring higher than 54% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 326,177 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 49th percentile – i.e., 49% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 100 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 61% of its contemporaries.