↓ Skip to main content

Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracers

Overview of attention for article published in European Journal of Nuclear Medicine and Molecular Imaging, June 2015
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users

Citations

dimensions_citation
39 Dimensions

Readers on

mendeley
57 Mendeley
citeulike
2 CiteULike
Title
Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracers
Published in
European Journal of Nuclear Medicine and Molecular Imaging, June 2015
DOI 10.1007/s00259-015-3082-x
Pubmed ID
Authors

Ninon Burgos, M. Jorge Cardoso, Kris Thielemans, Marc Modat, John Dickson, Jonathan M. Schott, David Atkinson, Simon R. Arridge, Brian F. Hutton, Sébastien Ourselin

Abstract

Positron Emission Tomography/Magnetic Resonance Imaging (PET/MR) scanners are expected to offer a new range of clinical applications. Attenuation correction is an essential requirement for quantification of PET data but MRI images do not directly provide a patient-specific attenuation map. Methods We further validate and extend a Computed Tomography (CT) and attenuation map (μ-map) synthesis method based on pre-acquired MRI-CT image pairs. The validation consists of comparing the CT images synthesised with the proposed method to the original CT images. PET images were acquired using two different tracers ((18)F-FDG and (18)F-florbetapir). They were then reconstructed and corrected for attenuation using the synthetic μ-maps and compared to the reference PET images corrected with the CT-based μ-maps. During the validation, we observed that the CT synthesis was inaccurate in areas such as the neck and the cerebellum, and propose a refinement to mitigate these problems, as well as an extension of the method to multi-contrast MRI data. Results With the improvements proposed, a significant enhancement in CT synthesis, which results in a reduced absolute error and a decrease in the bias when reconstructing PET images, was observed. For both tracers, on average, the absolute difference between the reference PET images and the PET images corrected with the proposed method was less than 2%, with a bias inferior to 1%. Conclusion With the proposed method, attenuation information can be accurately derived from MRI images by synthesising CT using routine anatomical sequences. MRI sequences, or combination of sequences, can be used to synthesise CT images, as long as they provide sufficient anatomical information.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 57 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United Kingdom 1 2%
Denmark 1 2%
Germany 1 2%
Unknown 54 95%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 16 28%
Researcher 14 25%
Other 4 7%
Professor > Associate Professor 4 7%
Student > Doctoral Student 3 5%
Other 8 14%
Unknown 8 14%
Readers by discipline Count As %
Medicine and Dentistry 14 25%
Physics and Astronomy 8 14%
Computer Science 6 11%
Engineering 6 11%
Neuroscience 3 5%
Other 7 12%
Unknown 13 23%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 18 April 2016.
All research outputs
#16,042,980
of 23,806,312 outputs
Outputs from European Journal of Nuclear Medicine and Molecular Imaging
#1,980
of 3,083 outputs
Outputs of similar age
#156,523
of 265,349 outputs
Outputs of similar age from European Journal of Nuclear Medicine and Molecular Imaging
#28
of 59 outputs
Altmetric has tracked 23,806,312 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,083 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 6.1. This one is in the 28th percentile – i.e., 28% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 265,349 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 32nd percentile – i.e., 32% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 59 others from the same source and published within six weeks on either side of this one. This one is in the 37th percentile – i.e., 37% of its contemporaries scored the same or lower than it.