↓ Skip to main content

Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia

Overview of attention for article published in Journal of Artificial Organs, June 2018
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
30 Mendeley
Title
Rapid-onset plasma leakage of extracorporeal oxygenation membranes possibly due to hyperbilirubinemia
Published in
Journal of Artificial Organs, June 2018
DOI 10.1007/s10047-018-1051-4
Pubmed ID
Authors

Yoshiko Kida, Shinichiro Ohshimo, Michihito Kyo, Yuko Tanabe, Kei Suzuki, Koji Hosokawa, Nobuaki Shime

Abstract

Extracorporeal membrane oxygenation (ECMO) is an emerging tool for supporting cardiopulmonary function in patients with cardiorespiratory failure or arrest. The oxygenator of the ECMO circuit requires effective oxygenation and removal of carbon dioxide from the blood. Major problems that can occur with the oxygenator include plasma leakage, one of the late-onset serious complications necessitating device replacement. However, the rapid onset of plasma leakage is rare. We present a 1-year-old boy with acute respiratory failure due to Pneumocystis and Aspergillus pneumonia. He presented with tachypnea, tachycardia, and hypoxemia despite the ventilatory support, and was therefore placed on venoarterial ECMO with a drainage catheter from the right internal jugular vein (12 Fr) and a return catheter to the right internal carotid artery (10 Fr). Extracorporeal circulation was initiated at a blood flow of 1 L/min (145 mL/kg/min) and a sweep gas flow of 1 L/min with FiO2 of 0.7. Although he was successfully weaned from the venoarterial ECMO on day 15 with an improvement of cardiopulmonary function, he was later placed on venoarterial ECMO again because of the progression of pulmonary hypertension. Laboratory tests showed increased concentrations of hepatic enzymes and hyperbilirubinemia (total bilirubin 31.6 mg/dL). Six hours after starting ECMO circulation, plasma leakage from the oxygenator occurred. Although we replaced the oxygenator with a new one, the replacement showed plasma leakage after 6 h. Disassembly of the oxygenator revealed congestion from bilirubin in the membrane fibers. We described a case of repeated, rapid-onset plasma leakage after implementation of ECMO. Hyperbilirubinemia was likely associated with the plasma leakage of this patient.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 30 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 30 100%

Demographic breakdown

Readers by professional status Count As %
Other 3 10%
Student > Bachelor 3 10%
Student > Ph. D. Student 3 10%
Professor > Associate Professor 3 10%
Student > Master 2 7%
Other 3 10%
Unknown 13 43%
Readers by discipline Count As %
Medicine and Dentistry 11 37%
Nursing and Health Professions 3 10%
Computer Science 1 3%
Immunology and Microbiology 1 3%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Other 4 13%
Unknown 9 30%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 04 June 2018.
All research outputs
#20,518,141
of 23,085,832 outputs
Outputs from Journal of Artificial Organs
#198
of 247 outputs
Outputs of similar age
#289,385
of 329,907 outputs
Outputs of similar age from Journal of Artificial Organs
#6
of 7 outputs
Altmetric has tracked 23,085,832 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 247 research outputs from this source. They receive a mean Attention Score of 4.6. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 329,907 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 7 others from the same source and published within six weeks on either side of this one.