↓ Skip to main content

Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry

Overview of attention for article published in Physics in Medicine & Biology, August 2015
Altmetric Badge

About this Attention Score

  • Above-average Attention Score compared to outputs of the same age and source (60th percentile)

Mentioned by

twitter
2 X users

Readers on

mendeley
62 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry
Published in
Physics in Medicine & Biology, August 2015
DOI 10.1088/0031-9155/60/17/6613
Pubmed ID
Authors
Abstract

The objective of this study was to characterize the time-resolved (TR) optically stimulated luminescence (OSL) from Al2O3:C detectors and investigate methodologies to improve the accuracy of these detectors in ion beam therapy dosimetry, addressing the reduction in relative response to high linear energy transfer (LET) particles common to solid-state detectors. Al2O3:C OSL detectors (OSLDs) were exposed to proton, (4)He, (12)C and (16)O beams in 22 particle/energy combinations and read using a custom-built TR-OSL reader. The OSL response [Formula: see text], relative to (60)Co gamma dose to water, and the ratio between the UV and blue OSL emission bands of Al2O3:C (UV/blue ratio) were determined as a function of the LET. Monte-Carlo simulations with the multi-purpose interaction and transport code FLUKA were used to estimate the absorbed doses and particle energy spectra in the different irradiation conditions. The OSL responses [Formula: see text] varied from 0.980 (0.73 keV μm(-1)) to 0.288 (120.8 keV μm(-1)). The OSL UV/blue ratio varied by a factor of two in the investigated LET range, but the variation for (12)C beams was only 11%. OSLDs were also irradiated at different depths of carbon ion spread-out Bragg peaks (SOBPs), where it was shown that doses could be obtained with an accuracy of  ±2.0% at the entrance channel and within the SOBP using correction factors calculated based on the OSL responses obtained in this study. The UV/blue ratio did not allow accurate estimation of the dose-averaged LET for (12)C SOBPs, although the values obtained can be explained with the data obtained in this study and the additional information provided by the Monte-Carlo simulations. The results demonstrate that accurate OSLD dosimetry can be performed in ion beam therapy using appropriate corrections for the OSL response.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 62 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Geographical breakdown
Country Count As %
Japan 1 2%
Unknown 61 98%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 13 21%
Researcher 12 19%
Other 5 8%
Student > Master 5 8%
Student > Bachelor 3 5%
Other 5 8%
Unknown 19 31%
Readers by discipline
Readers by discipline Count As %
Physics and Astronomy 27 44%
Medicine and Dentistry 5 8%
Engineering 4 6%
Business, Management and Accounting 2 3%
Environmental Science 1 2%
Other 3 5%
Unknown 20 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 31 August 2015.
All research outputs
#21,642,356
of 27,377,461 outputs
Outputs from Physics in Medicine & Biology
#4,724
of 6,285 outputs
Outputs of similar age
#194,302
of 278,084 outputs
Outputs of similar age from Physics in Medicine & Biology
#44
of 125 outputs
Altmetric has tracked 27,377,461 research outputs across all sources so far. This one is in the 18th percentile – i.e., 18% of other outputs scored the same or lower than it.
So far Altmetric has tracked 6,285 research outputs from this source. They receive a mean Attention Score of 3.9. This one is in the 22nd percentile – i.e., 22% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 278,084 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 25th percentile – i.e., 25% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 125 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 60% of its contemporaries.