↓ Skip to main content

Flexible microfluidic cloth-based analytical devices using a low-cost wax patterning technique

Overview of attention for article published in Lab on a Chip - Miniaturisation for Chemistry & Biology, January 2012
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (93rd percentile)
  • High Attention Score compared to outputs of the same age and source (93rd percentile)

Mentioned by

news
1 news outlet
patent
4 patents

Citations

dimensions_citation
186 Dimensions

Readers on

mendeley
183 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Flexible microfluidic cloth-based analytical devices using a low-cost wax patterning technique
Published in
Lab on a Chip - Miniaturisation for Chemistry & Biology, January 2012
DOI 10.1039/c1lc20764d
Pubmed ID
Authors

Azadeh Nilghaz, Dedy H. B. Wicaksono, Dwi Gustiono, Fadzilah Adibah Abdul Majid, Eko Supriyanto, Mohammed Rafiq Abdul Kadir

Abstract

This paper describes the fabrication of microfluidic cloth-based analytical devices (μCADs) using a simple wax patterning method on cotton cloth for performing colorimetric bioassays. Commercial cotton cloth fabric is proposed as a new inexpensive, lightweight, and flexible platform for fabricating two- (2D) and three-dimensional (3D) microfluidic systems. We demonstrated that the wicking property of the cotton microfluidic channel can be improved by scouring in soda ash (Na(2)CO(3)) solution which will remove the natural surface wax and expose the underlying texture of the cellulose fiber. After this treatment, we fabricated narrow hydrophilic channels with hydrophobic barriers made from patterned wax to define the 2D microfluidic devices. The designed pattern is carved on wax-impregnated paper, and subsequently transferred to attached cotton cloth by heat treatment. To further obtain 3D microfluidic devices having multiple layers of pattern, a single layer of wax patterned cloth can be folded along a predefined folding line and subsequently pressed using mechanical force. All the fabrication steps are simple and low cost since no special equipment is required. Diagnostic application of cloth-based devices is shown by the development of simple devices that wick and distribute microvolumes of simulated body fluids along the hydrophilic channels into reaction zones to react with analytical reagents. Colorimetric detection of bovine serum albumin (BSA) in artificial urine is carried out by direct visual observation of bromophenol blue (BPB) colour change in the reaction zones. Finally, we show the flexibility of the novel microfluidic platform by conducting a similar reaction in a bent pinned μCAD.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 183 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 2 1%
Japan 1 <1%
Germany 1 <1%
Brazil 1 <1%
Unknown 178 97%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 50 27%
Researcher 26 14%
Student > Master 24 13%
Student > Bachelor 22 12%
Professor > Associate Professor 9 5%
Other 26 14%
Unknown 26 14%
Readers by discipline Count As %
Engineering 48 26%
Chemistry 36 20%
Agricultural and Biological Sciences 22 12%
Chemical Engineering 10 5%
Biochemistry, Genetics and Molecular Biology 9 5%
Other 19 10%
Unknown 39 21%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 16. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 30 November 2021.
All research outputs
#2,247,871
of 25,756,911 outputs
Outputs from Lab on a Chip - Miniaturisation for Chemistry & Biology
#405
of 5,997 outputs
Outputs of similar age
#15,738
of 251,834 outputs
Outputs of similar age from Lab on a Chip - Miniaturisation for Chemistry & Biology
#17
of 266 outputs
Altmetric has tracked 25,756,911 research outputs across all sources so far. Compared to these this one has done particularly well and is in the 91st percentile: it's in the top 10% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 5,997 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 7.4. This one has done particularly well, scoring higher than 93% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 251,834 tracked outputs that were published within six weeks on either side of this one in any source. This one has done particularly well, scoring higher than 93% of its contemporaries.
We're also able to compare this research output to 266 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 93% of its contemporaries.