↓ Skip to main content

Colorimetric determination of sialic acid based on boronic acid-mediated aggregation of gold nanoparticles

Overview of attention for article published in Microchimica Acta, August 2018
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
36 Dimensions

Readers on

mendeley
16 Mendeley
Title
Colorimetric determination of sialic acid based on boronic acid-mediated aggregation of gold nanoparticles
Published in
Microchimica Acta, August 2018
DOI 10.1007/s00604-018-2951-y
Pubmed ID
Authors

Titilope John Jayeoye, Wilairat Cheewasedtham, Chatchai Putson, Thitima Rujiralai

Abstract

The authors describe a rapid, sensitive and selective colorimetric assay for sialic acid (SA) based on the use of gold nanoparticles (AuNPs) modified with 3-aminophenylboronic acid (3-APBA) which acts as the recognition probe for SA. 3-APBA contains amino groups and boronic acid groups through which it can assemble on citrate stabilized AuNPs. It reacts with the cis-diol groups of SA by reversible formation of a cyclic boronate ester in slightly acidic buffer. Detection involves the sequential addition of AuNPs, phosphate buffer, 3-APBA and SA in a tube, vortex mixing, acquisition of photographic images or absorption spectra, and calculation of the result. The method is simple, rapid, and does not require cumbersome steps such as the preparation of stable boronic acid functionalized AuNPs as used in colorimetric sensing of saccharides. Under the optimum conditions, the ratio of absorbances at 700 and 520 nm increases linearly in the 0.15-1.00 mM SA concentrations range, and the detection limit is 60 µM. This is comparable to the detection limit obtained in other colorimetric assays reported. Acceptable intra- and inter-day precisions of three SA concentrations (0.50, 1.00 and 2.00 mM) ranged from 1.9-4.2% and 4.2-6.4%, respectively. The efficacy of the method was demonstrated by analyzing simulated human saliva which gave recoveries ranging from 98.7-106.0%. Graphical abstract Schematic of a colorimetric method for detection of sialic acid (SA) in simulated saliva. It is based on aggregation of gold nanoparticles with 3-aminophenyl boronic acid (3-APBA) which assembles on AuNPs while the boronic acid group binds to cis-diols of SA to form a boronate ester.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 16 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 16 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 3 19%
Student > Master 2 13%
Researcher 2 13%
Student > Bachelor 1 6%
Unknown 8 50%
Readers by discipline Count As %
Chemistry 4 25%
Chemical Engineering 2 13%
Agricultural and Biological Sciences 1 6%
Pharmacology, Toxicology and Pharmaceutical Science 1 6%
Unknown 8 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 13 August 2018.
All research outputs
#20,529,980
of 23,099,576 outputs
Outputs from Microchimica Acta
#1,040
of 1,403 outputs
Outputs of similar age
#289,023
of 331,118 outputs
Outputs of similar age from Microchimica Acta
#15
of 35 outputs
Altmetric has tracked 23,099,576 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,403 research outputs from this source. They receive a mean Attention Score of 2.4. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 331,118 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 35 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.