↓ Skip to main content

Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data

Overview of attention for article published in Magnetic Resonance in Medicine, February 2016
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (92nd percentile)
  • High Attention Score compared to outputs of the same age and source (96th percentile)

Mentioned by

twitter
1 X user
patent
9 patents

Readers on

mendeley
156 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CEST MRI data
Published in
Magnetic Resonance in Medicine, February 2016
DOI 10.1002/mrm.26133
Pubmed ID
Authors
Abstract

Together with the development of MRI contrasts that are inherently small in their magnitude, increased magnetic field accuracy is also required. Hence, mapping of the static magnetic field (B0 ) and the excitation field (B1 ) is not only important to feedback shim algorithms, but also for postprocess contrast-correction procedures. A novel field-inhomogeneity mapping method is presented that allows simultaneous mapping of the water shift and B1 (WASABI) using an off-resonant rectangular preparation pulse. The induced Rabi oscillations lead to a sinc-like spectrum in the frequency-offset dimension and allow for determination of B0 by its symmetry axis and of B1 by its oscillation frequency. Stability of the WASABI method with regard to the influences of T1 , T2 , magnetization transfer, and repetition time was investigated and its convergence interval was verified. B0 and B1 maps obtained simultaneously by means of WASABI in the human brain at 3 T and 7 T can compete well with maps obtained by standard methods. Finally, the method was applied successfully for B0 and B1 correction of chemical exchange saturation transfer MRI (CEST-MRI) data of the human brain. The proposed WASABI method yields a novel simultaneous B0 and B1 mapping within 1 min that is robust and easy to implement. Magn Reson Med, 2016. © 2016 Wiley Periodicals, Inc.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 156 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
United States 1 <1%
United Kingdom 1 <1%
Austria 1 <1%
Unknown 153 98%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 40 26%
Researcher 22 14%
Student > Master 17 11%
Student > Bachelor 10 6%
Student > Postgraduate 9 6%
Other 15 10%
Unknown 43 28%
Readers by discipline
Readers by discipline Count As %
Physics and Astronomy 30 19%
Engineering 22 14%
Medicine and Dentistry 19 12%
Neuroscience 16 10%
Chemistry 6 4%
Other 13 8%
Unknown 50 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 19. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 22 July 2025.
All research outputs
#2,403,247
of 34,089,221 outputs
Outputs from Magnetic Resonance in Medicine
#108
of 8,380 outputs
Outputs of similar age
#33,860
of 456,627 outputs
Outputs of similar age from Magnetic Resonance in Medicine
#3
of 132 outputs
Altmetric has tracked 34,089,221 research outputs across all sources so far. Compared to these this one has done particularly well and is in the 92nd percentile: it's in the top 10% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 8,380 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.3. This one has done particularly well, scoring higher than 98% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 456,627 tracked outputs that were published within six weeks on either side of this one in any source. This one has done particularly well, scoring higher than 92% of its contemporaries.
We're also able to compare this research output to 132 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 96% of its contemporaries.