↓ Skip to main content

Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging

Overview of attention for article published in Journal of Plastic, Reconstructive & Aesthetic Surgery (JPRAS), March 2016
Altmetric Badge

Citations

dimensions_citation
28 Dimensions

Readers on

mendeley
26 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging
Published in
Journal of Plastic, Reconstructive & Aesthetic Surgery (JPRAS), March 2016
DOI 10.1016/j.bjps.2016.02.015
Pubmed ID
Authors

Johan Zötterman, Max Bergkvist, Fredrik Iredahl, Erik Tesselaar, Simon Farnebo

Abstract

In microsurgery, there is a demand for more reliable methods of post-operative monitoring of free flaps, especially with regard to tissue-threatening obstructions of the feeding arteries and draining veins. In this study, we evaluated laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) to assess their possibilities to detect partial and full venous outflow obstruction, as well as full arterial occlusion, in a porcine flap model. Cranial gluteal artery perforator flaps (CGAPs) were raised, and arterial and venous blood flow to and from the flaps was monitored using ultrasonic flow probes. The venous flow was altered with an inflatable cuff to simulate partial and full (50% and 100%) venous obstruction, and arterial flow was completely obstructed using clamps. The flap microcirculation was monitored using LSCI and LDF. Both LDF and the LSCI detected significant changes in flap perfusion. After partial (50%) venous occlusion, perfusion decreased from baseline, LSCI: 63.5 ± 12.9 PU (p = 0.01), LDF 31.3 ± 15.7 (p = 0.64). After 100% venous occlusion, a further decrease in perfusion was observed: LSCI 54.6 ± 14.2 PU (p < 0.001) and LDF 16.7 ± 12.8 PU (p < 0.001). After release of the venous cuff, LSCI detected a return of the perfusion to a level slightly, but not significantly, below the baseline level 70.1 ± 11.5 PU (p = 0.39), while the LDF signal returned to a level not significant from the baseline 36.1 ± 17.9 PU (p > 0.99). Perfusion during 100% arterial occlusion decreased significantly as measured with both methods, LSCI: 48.3 ± 7.7 (PU, p < 0.001) and LDF: 8.5 ± 4.0 PU (p < 0.001). During 50% and 100% venous occlusion, LSCI showed a 20% and 26% intersubject variability (CV%), respectively, compared to 50% and 77% for LDF. LSCI offers sensitive and reproducible measurements of flap microcirculation and seems more reliable in detecting decreases in blood perfusion caused by venous obstruction. It also allows for perfusion measurements in a relatively large area of flap tissue. This may be useful in identifying areas of the flap with compromised microcirculation during and after surgery.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 26 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Switzerland 1 4%
Unknown 25 96%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 6 23%
Student > Master 4 15%
Researcher 4 15%
Lecturer > Senior Lecturer 2 8%
Professor 1 4%
Other 3 12%
Unknown 6 23%
Readers by discipline Count As %
Medicine and Dentistry 11 42%
Engineering 4 15%
Physics and Astronomy 1 4%
Chemical Engineering 1 4%
Materials Science 1 4%
Other 1 4%
Unknown 7 27%