↓ Skip to main content

A randomized trial to evaluate a modified tracheal catheter with upper and lower balloons for anesthetic administration: effect on the cardiovascular, stress response, and comfort in patients…

Overview of attention for article published in BMC Anesthesiology, November 2019
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
2 Dimensions

Readers on

mendeley
33 Mendeley
Title
A randomized trial to evaluate a modified tracheal catheter with upper and lower balloons for anesthetic administration: effect on the cardiovascular, stress response, and comfort in patients undergoing laparoscopic cholecystectomy
Published in
BMC Anesthesiology, November 2019
DOI 10.1186/s12871-019-0883-7
Pubmed ID
Authors

Yuenong Zhang, Zhiwen Zeng, Guangwen Xiao, Weiqiang Zhang, Weixiong Lin, Jingdan Deng

Abstract

We aimed to evaluate a modified endotracheal tube containing upper and lower balloons for anesthetic administration among patients undergoing laparoscopic cholecystectomy. Ninety patients scheduled to undergo laparoscopic cholecystectomy were randomly allocated to 3 equal groups: group A (conventional tracheal intubation without endotracheal anesthesia); B (conventional tracheal intubation with endotracheal anesthesia); and C (tracheal intubation using a modified catheter under study). Blood pressure, heart rate, angiotensin II level, blood glucose level, airway pressure before anesthesia (T1) were measured immediately after intubation (T2), 5 min after intubation (T3), and immediately after extubation (T4). The post-extubation pain experienced was evaluated using the Wong-Baker Face Pain scale. Adverse reactions within 30 min after extubation were recorded. Systolic blood pressure, diastolic blood pressure, angiotensin II, and blood sugar level in group C at T2, T3 and T4, and heart rate at T2 and T4 were significantly lower than those in group A (P < 0.05); systolic blood pressure and blood sugar at T4, and angiotensin II levels at T2, T3, and T4 were significantly lower than those in group B (P < 0.05). Patients in group C reported the lowest post-extubation pain (P < 0.05 vs. Group A), and the lowest incidence of adverse events such as nausea, vomiting, and sore throat than that in groups A and B (P < 0.05). The modified endotracheal anesthesia tube under study is effective in reducing cardiovascular and tracheal stress response, and increasing patient comfort, without inducing an increase in airway resistance. The clinical trial was retrospectively registered at the Chinese Clinical Trial Registry with the Registration Number ChiCTR1900020832 at January 20th 2019.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 33 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 33 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 4 12%
Student > Doctoral Student 4 12%
Unspecified 3 9%
Lecturer 3 9%
Other 1 3%
Other 2 6%
Unknown 16 48%
Readers by discipline Count As %
Medicine and Dentistry 8 24%
Nursing and Health Professions 4 12%
Unspecified 3 9%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Unknown 17 52%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 19 November 2019.
All research outputs
#20,590,073
of 23,175,240 outputs
Outputs from BMC Anesthesiology
#1,198
of 1,524 outputs
Outputs of similar age
#304,358
of 358,534 outputs
Outputs of similar age from BMC Anesthesiology
#36
of 50 outputs
Altmetric has tracked 23,175,240 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,524 research outputs from this source. They receive a mean Attention Score of 3.2. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 358,534 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 50 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.