Postoperative environmental anesthetic vapour concentrations following removal of the airway device in the operating room versus the postanesthesia care unit

Overview of attention for article published in Canadian Journal of Anesthesia/Journal canadien d'anesthésie, June 2016
Altmetric Badge

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
13 Mendeley
Title
Postoperative environmental anesthetic vapour concentrations following removal of the airway device in the operating room versus the postanesthesia care unit
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie, June 2016
DOI 10.1007/s12630-016-0678-y
Pubmed ID
Authors

Sara K. Cheung, Timur Özelsel, Saifee Rashiq, Ban C. Tsui

Abstract

This study was designed to compare waste anesthetic gas (WAG) concentrations within patients' breathing zones after removal of the patient's airway device in the postanesthesia care unit (PACU) vs in the operating room (OR). Following Research Ethics Board approval and patient consent, we recruited patients undergoing surgery who received volatile anesthesia via an endotracheal tube or supraglottic airway. Patients had their airway device removed in the OR or in the PACU depending on the attending anesthesiologist's preference. Upon the patient's arrival in the PACU, concentrations of exhaled sevoflurane and desflurane were measured at their breathing zone (i.e., 15 cm from the patient's mouth and nose) using a single-beam infrared spectrophotometer. Seventy patients were recruited during the five-month study period. The median [interquartile range] WAG levels in the patients' breathing zones were higher when their airway devices were removed in the PACU vs in the OR. The WAG levels for sevoflurane were 0.7 [0.4-1.1] parts per million (ppm) vs 0.5 [0.4-0.7] ppm, respectively; median difference, 0.3; 95% confidence interval (CI), 0.1 to 0.6; P = 0.04. The WAG levels for desflurane were 2.4 [1.2-3.4] ppm vs 4.1 [2.5-5.2] ppm, respectively; median difference, 1.5; 95% CI, 0.3 to 2.7; P = 0.04. After a volatile-based anesthetic, our results suggest that removal of the airway device in the PACU vs in the OR increases the amount of waste anesthetic gas in a patient's breathing zone and thus potentially in the PACU nurse's working zone.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 13 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 13 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 2 15%
Researcher 2 15%
Student > Ph. D. Student 2 15%
Other 1 8%
Lecturer 1 8%
Other 1 8%
Unknown 4 31%
Readers by discipline Count As %
Medicine and Dentistry 6 46%
Chemistry 1 8%
Nursing and Health Professions 1 8%
Unknown 5 38%