↓ Skip to main content

Bulk evaluation and comparison of radiotherapy treatment plans for breast cancer

Overview of attention for article published in Physical and Engineering Sciences in Medicine, June 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
4 Dimensions

Readers on

mendeley
14 Mendeley
Title
Bulk evaluation and comparison of radiotherapy treatment plans for breast cancer
Published in
Physical and Engineering Sciences in Medicine, June 2016
DOI 10.1007/s13246-016-0454-x
Pubmed ID
Authors

T. Kairn, S. B. Crowe, C. M. Langton, J. V. Trapp

Abstract

This study provides a bulk, retrospective analysis of 151 breast and chest wall radiotherapy treatment plans, as a small-scale demonstration of the potential breadth and value of the information that may be obtained from clinical data mining. The treatments were planned at three centres belonging to one organisation over a period of 3 months. All 151 plans were used to evaluate inter-centre consistency and compliance with a local planning protocol. A subset of 79 plans, from one centre, were used in a more detailed evaluation of the effects of anatomical asymmetry on heart and lung dose, the effects of a metallic temporary tissue expander port on dose homogeneity and the overall conformity and homogeneity achieved in routine breast treatment planning. Differences in anatomical structure contouring and nomenclature were identified between the three centres, with all centres showing some non-compliance with the local planning protocol. When evaluated against standard conformity indices, these breast plans performed relatively poorly. However, when evaluated against recommended organ-at-risk tolerances, all evaluated plans performed sufficiently well that tighter planning tolerances could be recommended for future planning. Heart doses calculated in left breast and chest wall treatments were significantly higher than heart doses calculated in right sided breast and chest wall treatments (p < 0.001). In the treatment involving a temporary tissue expander, the inflated implant effectively pushed the targeted breast tissue away from the healthy tissues, leading to a dose distribution that was relatively conformal, although attenuation through the tissue expander's metallic port may have been underestimated by the treatment planning system. The results of this study exemplify the use of bulk treatment planning data to evaluate clinical workloads and inform ongoing treatment planning.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 14 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 14 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 4 29%
Researcher 4 29%
Other 2 14%
Professor 1 7%
Professor > Associate Professor 1 7%
Other 0 0%
Unknown 2 14%
Readers by discipline Count As %
Medicine and Dentistry 4 29%
Nursing and Health Professions 2 14%
Physics and Astronomy 2 14%
Computer Science 1 7%
Social Sciences 1 7%
Other 1 7%
Unknown 3 21%