↓ Skip to main content

An Experimental and Computational Study on the Effect of Caval Valved Stent Oversizing

Overview of attention for article published in Cardiovascular Engineering and Technology, June 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
8 Dimensions

Readers on

mendeley
15 Mendeley
Title
An Experimental and Computational Study on the Effect of Caval Valved Stent Oversizing
Published in
Cardiovascular Engineering and Technology, June 2016
DOI 10.1007/s13239-016-0268-8
Pubmed ID
Authors

Munirah Ismail, Gideon Praveen Kumar, Foad Kabinejadian, Yen Ngoc Nguyen, Fangsen Cui, Edgar Lik Wui Tay, Hwa Liang Leo

Abstract

Heterotopic implantation of transcatheter tricuspid valve is a new treatment option for tricuspid regurgitation. Transcatheter tricuspid valves are implanted onto the cavoatrial junction in order to avoid the challenging task of anchoring the valve onto the complex tricuspid valve annulus. However, little is known about optimum extent of oversizing of the valved stent in a vena cava. In this study, we implanted valves of the same diameter onto the larger sized inferior vena cava (IVC) and a smaller sized superior vena cava (SVC). The valve in the IVC was oversized by 10.7% while the valve in the SVC was oversized by 21.6%. Finite element analysis was performed (i) to assess the strain on the nitinol stent during manufacturing and deployment; (ii) the stents were deployed in a patient-specific vena cava model and the intramural stress of the vena cava was calculated computationally. These valves were fabricated and placed in a silicone model of a patient-specific right atrium which was part of a mock circulatory system that emulated the patho-physiological flow rate and pressure of a patient with tricuspid regurgitation. Flow measurements were conducted by particle image velocimetry (PIV). It was found that the maximum crimping strain on the nitinol stent was 6.85% which was lower than the critical threshold of 10%. The maximum stress on the vena cava was located at the spot where the hooks met the wall. The maximum stress on the IVC was 0.5098 MPa while the maximum stress on the SVC was 0.7 MPa. The maximum Reynolds shear stress (mRSS) in the vena cava was found to be higher in the IVC than SVC with the highest mRSS being 1741 dynes/cm(2) found in the region of high flow during the peak flow phase. The overtly oversized valve in the SVC did not cause flow disturbances and exhibited mostly laminar flows. The mRSS at the downstream of the vena cava valve and the middle of the atrium remained at low magnitudes. However, velocity fluctuations were high in the IVC in all the time points measured. In conclusion, oversizing the valve may assist anchorage; yet, careful consideration should be taken in choosing the extent of oversizing as it may lead to adverse effects.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 15 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 15 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 3 20%
Other 2 13%
Unspecified 1 7%
Student > Bachelor 1 7%
Student > Doctoral Student 1 7%
Other 2 13%
Unknown 5 33%
Readers by discipline Count As %
Medicine and Dentistry 4 27%
Engineering 3 20%
Biochemistry, Genetics and Molecular Biology 1 7%
Psychology 1 7%
Unspecified 1 7%
Other 0 0%
Unknown 5 33%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 07 July 2016.
All research outputs
#18,465,704
of 22,880,230 outputs
Outputs from Cardiovascular Engineering and Technology
#134
of 174 outputs
Outputs of similar age
#267,436
of 352,012 outputs
Outputs of similar age from Cardiovascular Engineering and Technology
#3
of 3 outputs
Altmetric has tracked 22,880,230 research outputs across all sources so far. This one is in the 11th percentile – i.e., 11% of other outputs scored the same or lower than it.
So far Altmetric has tracked 174 research outputs from this source. They receive a mean Attention Score of 3.7. This one is in the 10th percentile – i.e., 10% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 352,012 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 13th percentile – i.e., 13% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 3 others from the same source and published within six weeks on either side of this one.