↓ Skip to main content

A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery

Overview of attention for article published in Brazilian Journal of Anesthesiology, October 2014
Altmetric Badge

Mentioned by

googleplus
1 Google+ user

Citations

dimensions_citation
5 Dimensions

Readers on

mendeley
29 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery
Published in
Brazilian Journal of Anesthesiology, October 2014
DOI 10.1016/j.bjane.2014.07.004
Pubmed ID
Authors

Bikramjit Das, Rajiv Kumar Samal, Arup Ghosh, Ratul Kundu

Abstract

We compared intraocular pressure changes following laryngoscopy and intubation with conventional Macintosh blade and Airtraq optical laryngoscope. Ninety adult patients were randomly assigned to study group or control group. Study group (n=45) - Airtraq laryngoscope was used for laryngoscopy. Control group (n=45) - conventional Macintosh laryngoscope was used for laryngoscopy. Preoperative baseline intraocular pressure was measured with Schiotz tonometer. Laryngoscopy was done as per group protocol. Intraocular pressure and haemodynamic parameters were recorded just before insertion of the device and subsequently three times at an interval of one minute after insertion of the device. Patient characteristics, baseline haemodynamic parameters and baseline intraocular pressure were comparable in the two groups. Following insertion of the endotracheal tube with Macintosh laryngoscope, there was statistically significant rise in heart rate and intraocular pressure compared to Airtraq group. There was no significant change in MAP. Eight patients in Macintosh group had tongue-lip-dental trauma during intubation, while only 2 patients received upper airway trauma in Airtraq group. We conclude that Airtraq laryngoscope in comparison to Macintosh laryngoscope results in significantly fewer rises in intraocular pressure and clinically less marked increase in haemodynamic response to laryngoscopy and intubation.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 29 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Brazil 1 3%
Unknown 28 97%

Demographic breakdown

Readers by professional status Count As %
Student > Master 8 28%
Student > Bachelor 5 17%
Other 4 14%
Student > Doctoral Student 3 10%
Student > Postgraduate 2 7%
Other 2 7%
Unknown 5 17%
Readers by discipline Count As %
Medicine and Dentistry 15 52%
Psychology 2 7%
Unspecified 1 3%
Biochemistry, Genetics and Molecular Biology 1 3%
Nursing and Health Professions 1 3%
Other 2 7%
Unknown 7 24%