↓ Skip to main content

Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy

Overview of attention for article published in Brazilian Journal of Anesthesiology, April 2016
Altmetric Badge

Citations

dimensions_citation
12 Dimensions

Readers on

mendeley
56 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy
Published in
Brazilian Journal of Anesthesiology, April 2016
DOI 10.1016/j.bjane.2015.08.015
Pubmed ID
Authors

Oznur Sen, Yasemin Erdogan Doventas

Abstract

General anesthesia causes reduction of functional residual capacity. And this decrease can lead to atelectasis and intrapulmonary shunting in the lung. In this study we want to evaluate the effects of 5 and 10cmH2O PEEP levels on gas exchange, hemodynamic, respiratory mechanics and systemic stress response in laparoscopic cholecystectomy. American Society of Anesthesiologist I-II physical status 43 patients scheduled for laparoscopic cholecystectomy were randomly selected to receive external PEEP of 5cmH2O (PEEP 5 group) or 10cmH2O PEEP (PEEP 10 group) during pneumoperitoneum. Basal hemodynamic parameters were recorded, and arterial blood gases (ABG) and blood sampling were done for cortisol, insulin and glucose level estimations to assess the systemic stress response before induction of anesthesia. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, and glucose levels were repeated. Lastly hemodynamic parameters were recorded; ABG analysis and sampling for stress response levels were taken after 60minutes from extubation. There were no statistical differences between the two groups about hemodynamic and respiratory parameters except mean airway pressure (Pmean). Pmean, compliance and PaO2; pH values were higher in 'PEEP 10 group'. Also, PaCO2 values were lower in 'PEEP 10 group'. No differences were observed between insulin and lactic acid levels in the two groups. But postoperative cortisol level was significantly lower in 'PEEP 10 group'. Ventilation with 10cmH2O PEEP increases compliance and oxygenation, does not cause hemodynamic and respiratory complications and reduces the postoperative stress response.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 56 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 56 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 7 13%
Student > Bachelor 7 13%
Other 5 9%
Student > Master 4 7%
Student > Doctoral Student 3 5%
Other 8 14%
Unknown 22 39%
Readers by discipline Count As %
Medicine and Dentistry 15 27%
Agricultural and Biological Sciences 3 5%
Psychology 3 5%
Nursing and Health Professions 3 5%
Physics and Astronomy 2 4%
Other 7 13%
Unknown 23 41%