↓ Skip to main content

Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir*

Overview of attention for article published in Radiologia Brasileira, January 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Readers on

mendeley
4 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir*
Published in
Radiologia Brasileira, January 2016
DOI 10.1590/0100-3984.2015.0010
Pubmed ID
Authors

Tarcísio Passos Ribeiro de Campos, Carla Flavia de Lima, Ethel Mizrahy Cuperschmid

Abstract

To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with (99m)Tc and balloon brachytherapy with high-dose-rate (HDR) (192)Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Simulations of implants with (99m)Tc-filled and HDR (192)Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. The (99m)Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h(-1).mCi(-1) and 0.190 cGyh(-1).mCi(-1) at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh(-1).mCi(-1), respectively, for the HDR (192)Ir balloon. An exposure time of 24 hours was required for the (99m)Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR (192)Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Temporary (99m)Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR (192)Ir balloon implantation, which is the current standard in clinical practice.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 4 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 4 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 1 25%
Student > Doctoral Student 1 25%
Unknown 2 50%
Readers by discipline Count As %
Medicine and Dentistry 2 50%
Unknown 2 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 04 May 2016.
All research outputs
#22,759,452
of 25,374,647 outputs
Outputs from Radiologia Brasileira
#303
of 394 outputs
Outputs of similar age
#341,814
of 399,679 outputs
Outputs of similar age from Radiologia Brasileira
#23
of 35 outputs
Altmetric has tracked 25,374,647 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 394 research outputs from this source. They receive a mean Attention Score of 2.1. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 399,679 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 35 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.