↓ Skip to main content

Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite

Overview of attention for article published in Journal of Applied Oral Science, January 2017
Altmetric Badge

Mentioned by

facebook
1 Facebook page

Citations

dimensions_citation
15 Dimensions

Readers on

mendeley
39 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite
Published in
Journal of Applied Oral Science, January 2017
DOI 10.1590/1678-77572016-0388
Pubmed ID
Authors

Kelly Antonieta Oliveira Rodrigues de Faria Cardoso, Driellen Christine Zarpellon, Camila Ferreira Leite Madruga, José Augusto Rodrigues, Cesar Augusto Galvão Arrais

Abstract

Using Fourier transform infrared analysis (FTIR) in vitro, the effects of varying radiant exposure (RE) values generated by second and third generation LED LCUs on the degree of conversion (DC) and maximum rate of polymerization (Rpmax) of an experimental Lucirin TPO-based RC were evaluated. 1 mm or 2 mm thick silicon molds were positioned on a horizontal attenuated total reflectance (ATR) unit attached to an infrared spectroscope. The RC was inserted into the molds and exposed to varying REs (18, 36 and 56 J/cm2) using second (Radii Plus, SDI) and third generation LED LCUs (Bluephase G2/Ivoclar Vivadent) or a quartz tungsten based LCU (Optilux 501/SDS Kerr). FTIR spectra (n=7) were recorded for 10 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm-1) immediately after their application to the ATR. The DC was calculated using standard techniques for observing changes in aliphatic to aromatic peak ratios both prior to, and 10 min after curing, as well as during each 1 second interval. DC and Rpmax data were analyzed using 3-way ANOVA and Tukey's post-hoc test (p=0.05). No significant difference in DC or Rpmax was observed between the 1 mm or 2 mm thick specimens when RE values were delivered by Optilux 501 or when the 1 mm thick composites were exposed to light emitted by Bluephase G2, which in turn promoted a lower DC when 18 J/cm2 (13 s) were delivered to the 2 mm thick specimens. Radii Plus promoted DC and Rpmax values close to zero under most conditions, while the delivery of 56 J/cm2 (40 s) resulted in low DC values. The third generation LCU provided an optimal polymerization of Lucirin TPO-based RC under most tested conditions, whereas the second generation LED-curing unit was useless regardless of the RE.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 39 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 39 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 4 10%
Student > Master 4 10%
Professor 4 10%
Student > Doctoral Student 3 8%
Student > Bachelor 3 8%
Other 9 23%
Unknown 12 31%
Readers by discipline Count As %
Medicine and Dentistry 18 46%
Unspecified 2 5%
Engineering 2 5%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Social Sciences 1 3%
Other 3 8%
Unknown 12 31%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 May 2017.
All research outputs
#22,764,772
of 25,382,440 outputs
Outputs from Journal of Applied Oral Science
#496
of 596 outputs
Outputs of similar age
#362,560
of 421,709 outputs
Outputs of similar age from Journal of Applied Oral Science
#21
of 28 outputs
Altmetric has tracked 25,382,440 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 596 research outputs from this source. They receive a mean Attention Score of 3.4. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 421,709 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 28 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.