↓ Skip to main content

Assessment of retinal nerve fiber thickness and optic nerve head blood flow in female patients diagnosed with fibromyalgia syndrome.

Overview of attention for article published in Arquivos Brasileiros de Oftalmologia, January 2022
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • High Attention Score compared to outputs of the same age and source (83rd percentile)

Mentioned by

twitter
2 X users

Citations

dimensions_citation
2 Dimensions

Readers on

mendeley
20 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Assessment of retinal nerve fiber thickness and optic nerve head blood flow in female patients diagnosed with fibromyalgia syndrome.
Published in
Arquivos Brasileiros de Oftalmologia, January 2022
DOI 10.5935/0004-2749.20220005
Pubmed ID
Authors

Selma Urfalıoglu, Ejder Berk

Abstract

Numerous neuroimaging and ophthalmic studies suggest optic nerve involvement in fi-bromyalgia syndrome. To further elucidate the etiopathogenesis of fibromyalgia syndrome, we compared optic nerve head blood flow area and retinal nerve fiber layer thickness between patients and controls and investigated the associations of these measures with fibromyalgia syndrome severity. Participants were divided into the following three groups according to Fibromyalgia Impact Questionnaire score: mild-moderate fibromyalgia syndrome (Group 1, n=47), severe fibromyalgia syndrome (Group 2, n=38), and healthy controls (Group 3, n=38). The optic nerve head blood flow area and retinal nerve fiber layer thickness were measured by optical coherence tomography angiography and compared among groups by ANOVA. Associations with fibromyalgia syndrome severity were evaluated by Spearman's correlation analysis. Optic nerve head blood flow area did not differ between fibromyalgia syndrome Groups 1 and 2 (1.61 ± 0.08 vs.1.63 ± 0.09 mm2), but it was significantly lower in control Group 3 (1.49 ± 0.10 mm2, all p=0.001). Average retinal nerve fiber layer thickness values were significantly lower in Group 2 (101.18 ± 6.03 mm) than in Group 1 (103.21 ± 10.66 mm) and Group 3 (106.51 ± 8.88 mm) (p=0.041 and 0.020, respectively). The inferotemporal (134.36 ± 12.19 mm) and inferonasal (109.47 ± 16.03 mm) quadrant retinal nerve fiber layer thickness values were significantly lower in Group 2 than in Group 1 [inferotemporal (142.15 ± 17.79 mm), inferonasal (117.94 ± 20.53 mm)] and Group 3 [inferotemporal (144.70 ± 16.25 mm), inferonasal (118.63 ± 19.01 mm)] [inferotemporal, p=0.017 and 0.010, respectively; inferonasal, p=0.047 and 0.045, respectively]. The nasal-superior quadrant retinal nerve fiber layer thickness value was higher in Group 3 (91.08 ± 12.11 mm) than in Group 1 (84.34 ± 13.09 mm) and Group 2 (85.26 ± 13.11 mm) (p=0.031 and 0.038, respectively). A weak correlation was detected between disease severity and optic nerve head blood flow area. Neural and vascular structures of the eye are altered in fibromyalgia syndrome, particularly among severe cases. Therefore, optical coherence tomography angiography may provide valuable information for the diagnosis and elucidation of fibromyalgia syndrome pathophysiology.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 20 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 20 100%

Demographic breakdown

Readers by professional status Count As %
Unspecified 4 20%
Professor 2 10%
Researcher 2 10%
Student > Doctoral Student 1 5%
Student > Master 1 5%
Other 1 5%
Unknown 9 45%
Readers by discipline Count As %
Unspecified 4 20%
Medicine and Dentistry 4 20%
Psychology 1 5%
Computer Science 1 5%
Social Sciences 1 5%
Other 1 5%
Unknown 8 40%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 07 October 2021.
All research outputs
#16,059,145
of 25,392,582 outputs
Outputs from Arquivos Brasileiros de Oftalmologia
#135
of 445 outputs
Outputs of similar age
#266,585
of 515,332 outputs
Outputs of similar age from Arquivos Brasileiros de Oftalmologia
#5
of 30 outputs
Altmetric has tracked 25,392,582 research outputs across all sources so far. This one is in the 34th percentile – i.e., 34% of other outputs scored the same or lower than it.
So far Altmetric has tracked 445 research outputs from this source. They receive a mean Attention Score of 2.5. This one has gotten more attention than average, scoring higher than 68% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 515,332 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 45th percentile – i.e., 45% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 30 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 83% of its contemporaries.