↓ Skip to main content

Rod Attachment Induces Significant Strain in Lumbosacral Fixation

Overview of attention for article published in Clinical Spine Surgery, February 2023
Altmetric Badge

Mentioned by

twitter
1 X user

Readers on

mendeley
7 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Rod Attachment Induces Significant Strain in Lumbosacral Fixation
Published in
Clinical Spine Surgery, February 2023
DOI 10.1097/bsd.0000000000001438
Pubmed ID
Authors
Abstract

This was a laboratory investigation. Rod attachment can induce significant pedicle screw-and-rod pre-strain that may predispose the instrumentation to failure. This study investigated how in vitro L5-S1 rod strain and S1 screw strain during rod-screw attachment (pre-strain) compared with strains recorded during pure-moment bending (test-strain). The lumbosacral junction is highly vulnerable to construct failure due to rod fatigue fracture, sacral screw pull-out, and screw fatigue fracture. Twelve cadaveric specimens were instrumented with L2-ilium pedicle screws and rod. Strain gauges on contoured rods and sacral screws recorded strains during sequential rod-to-screw tightening (pre-strains). The same instrumented constructs were immediately tested in a 6-degree-of-freedom apparatus under continuous loading to 7.5 Nm in multidirectional bending while recording instrumentation test-strains. Rod and screw pre-strains and test-strains were compared using 1-way repeated-measures analysis of variance followed by Holm-Šidák paired analysis (significant at P<0.05). The mean first (171±192 µE) and second (322±269 µE) rod attachment pre-strains were comparable to mean test-strains during flexion (265±109 µE) and extension (315±125 µE, P≥0.13). The mean rod attachment pre-strain was significantly greater than mean test-strains during bidirectional lateral bending (40±32 µE ipsilateral and 39±32 µE contralateral, P<0.001) and axial rotation (72±60 µE ipsilateral and 60±57 µE contralateral, P<0.001). The mean first and second sacral screw pre-strains during rod attachment (1.03±0.66 and 1.39±1.00 Nm, respectively) did not differ significantly (P=0.41); however, the mean sacral screw pre-strain during final (second) rod attachment was significantly greater than screw test-strains during all directions of movement (≤0.81 Nm, P≤0.03). Instrumentation pre-strains imposed during in vitro rod-screw attachment of seemingly well-contoured rods in L2-ilium fixation are comparable to, and at times greater than, strains experienced during in vitro bending. Spine surgeons should be aware of the biomechanical consequences of rod contouring and attachment on construct vulnerability.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 7 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 7 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Researcher 1 14%
Other 1 14%
Unknown 5 71%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 1 14%
Unknown 6 86%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 15 February 2023.
All research outputs
#18,905,628
of 27,412,402 outputs
Outputs from Clinical Spine Surgery
#1,018
of 1,976 outputs
Outputs of similar age
#308,683
of 524,856 outputs
Outputs of similar age from Clinical Spine Surgery
#10
of 15 outputs
Altmetric has tracked 27,412,402 research outputs across all sources so far. This one is in the 21st percentile – i.e., 21% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,976 research outputs from this source. They receive a mean Attention Score of 3.0. This one is in the 39th percentile – i.e., 39% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 524,856 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 28th percentile – i.e., 28% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 15 others from the same source and published within six weeks on either side of this one. This one is in the 26th percentile – i.e., 26% of its contemporaries scored the same or lower than it.