Influence of implant restorative emergence angle and contour on peri‐implant marginal bone loss: A systematic review and meta‐analysis

Overview of attention for article published in Clinical Implant Dentistry & Related Research, May 2023
Altmetric Badge

Mentioned by

twitter
1 X user

Readers on

mendeley
67 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Influence of implant restorative emergence angle and contour on peri‐implant marginal bone loss: A systematic review and meta‐analysis
Published in
Clinical Implant Dentistry & Related Research, May 2023
DOI 10.1111/cid.13214
Pubmed ID
Authors
Abstract

Implant restorative emergence angle and profile may have a negative impact on peri-implant marginal bone level and may increase the risk of developing peri-implantitis. However, the role of these prosthetic features on peri-implant health is still unclear. The aim of this systematic review and meta-analyses was to evaluate the long-term outcomes of implant restorations with an emergence angle of >30° in comparison to those with ≤30° in terms of changes in peri-implant marginal bone level, periodontal parameters, and prevalence rate of peri-implantitis. Electronic databases were searched to identify observational studies that compared implant restorations with an emergence angle of >30° to those with ≤30°. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. Four studies with 912 dental implants in 397 participants were included in the present review. Of these, 455 implants had restorations with an emergence angle of >30°, while the remaining implants had restorative emergence angle of ≤30°. The follow-up time varied between 3.8 and 10.9 years. Implant restorations with an emergence angle of ≤30° were associated with less changes in peri-implant marginal bone level compared to those with emergence angle of >30°. The difference, however, was not statistically significant (mean difference 0.80; 95% confidence interval (CI) -0.13 to 1.72; p = 0.09). In platform-matched implants, the difference between the two groups was statistically significant in favor of implant restorations with emergence angle of ≤30°. In terms of emergence profile, implant restorations with convex profile had significantly higher rate of peri-implantitis (57.8%) compared to implant restorations with concave or straight profile (21.3%) (risk ratio 2.32; 95% CI 1.12-4.82; p = 0.02). Within the limitation of this review, implant restorations with an emergence angles of >30° or ≤30° seem to have no significant influence on peri-implant marginal bone level. Platform-matched implants with an emergence angle of ≤30° may have positive effects on the peri-implant marginal bone level changes, but the evidence support is of low to moderate certainty.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 67 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 67 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Unspecified 8 12%
Student > Master 4 6%
Student > Postgraduate 4 6%
Student > Ph. D. Student 3 4%
Researcher 3 4%
Other 6 9%
Unknown 39 58%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 13 19%
Unspecified 8 12%
Business, Management and Accounting 1 1%
Agricultural and Biological Sciences 1 1%
Social Sciences 1 1%
Other 2 3%
Unknown 41 61%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 15 May 2023.
All research outputs
#31,230,895
of 34,412,533 outputs
Outputs from Clinical Implant Dentistry & Related Research
#380
of 469 outputs
Outputs of similar age
#371,830
of 426,407 outputs
Outputs of similar age from Clinical Implant Dentistry & Related Research
#4
of 6 outputs
Altmetric has tracked 34,412,533 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 469 research outputs from this source. They receive a mean Attention Score of 3.8. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 426,407 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one. This one has scored higher than 2 of them.