↓ Skip to main content

Minimum intraoperative testing battery for cochlear implantation: the international practice trend

Overview of attention for article published in European Archives of Oto-Rhino-Laryngology, September 2024
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (86th percentile)
  • High Attention Score compared to outputs of the same age and source (92nd percentile)

Mentioned by

twitter
9 X users
guideline
1 clinical guideline source

Readers on

mendeley
11 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Minimum intraoperative testing battery for cochlear implantation: the international practice trend
Published in
European Archives of Oto-Rhino-Laryngology, September 2024
DOI 10.1007/s00405-024-08944-y
Pubmed ID
Authors
Abstract

In cochlear implantation (CI) surgery, there are a wide variety of intraoperative tests available. However, no clear guide exists on which tests must be performed as the minimum intraoperative testing battery. Toward this end, we studied the usage patterns, recommendations, and attitudes of practitioners toward intraoperative testing. This study is a multicentric international survey of tertiary referral CI centers. A survey was developed and administered to a group of CI practitioners (n = 34) including otologists, audiologists and biomedical engineers. Thirty six participants were invited to participate in this study based on a their scientific outputs to the literature on the intraoperative testing in CI field and based on their high load of CI surgeries. Thirty four, from 15 countries have accepted the invitation to participate. The participants were asked to indicate the usage trends, perceived value, influence on decision making and duration of each intraoperative test. They were also asked to indicate which tests they believe should be included in a minimum test battery for routine cases. Thirty-two (94%) experts provided responses. The most frequently recommended tests for a minimum battery were facial nerve monitoring, electrode impedance measurements, and measurements of electrically evoked compound action potentials (ECAPs). The perceived value and influence on surgical decision-making also varied, with high-resolution CT being rated the highest on both measures. Facial nerve monitoring, electrode impedance measurements, and ECAP measurements are currently the core tests of the intraoperative test battery for CI surgery.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 9 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 11 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 11 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Researcher 2 18%
Other 1 9%
Student > Doctoral Student 1 9%
Student > Bachelor 1 9%
Student > Ph. D. Student 1 9%
Other 0 0%
Unknown 5 45%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 4 36%
Engineering 2 18%
Unknown 5 45%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 11. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 May 2025.
All research outputs
#4,385,844
of 34,546,575 outputs
Outputs from European Archives of Oto-Rhino-Laryngology
#221
of 4,423 outputs
Outputs of similar age
#46,770
of 338,443 outputs
Outputs of similar age from European Archives of Oto-Rhino-Laryngology
#3
of 39 outputs
Altmetric has tracked 34,546,575 research outputs across all sources so far. Compared to these this one has done well and is in the 87th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 4,423 research outputs from this source. They receive a mean Attention Score of 4.3. This one has done particularly well, scoring higher than 94% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 338,443 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 86% of its contemporaries.
We're also able to compare this research output to 39 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 92% of its contemporaries.