↓ Skip to main content

Micro‐computed tomographic analysis of the radial geometry of intrarenal artery‐vein pairs in rats and rabbits: Comparison with light microscopy

Overview of attention for article published in Clinical & Experimental Pharmacology & Physiology, September 2017
Altmetric Badge

Mentioned by

twitter
1 X user

Readers on

mendeley
17 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Micro‐computed tomographic analysis of the radial geometry of intrarenal artery‐vein pairs in rats and rabbits: Comparison with light microscopy
Published in
Clinical & Experimental Pharmacology & Physiology, September 2017
DOI 10.1111/1440-1681.12842
Pubmed ID
Authors
Abstract

We assessed the utility of synchrotron-radiation micro-computed tomography (micro-CT) for quantification of the radial geometry of the renal cortical vasculature. The kidneys of nine rats and six rabbits were perfusion fixed and the renal circulation filled with Microfil(®) . In order to assess shrinkage of Microfil(®) , rat kidneys were imaged at the Australian Synchrotron immediately upon tissue preparation and then post fixed in paraformaldehyde and reimaged 24 hours later. The Microfil(®) shrank only 2-5% over the 24 hour period. All subsequent micro-CT imaging was completed within 24 hours of sample preparation. After micro-CT imaging, the kidneys were processed for histological analysis. In both rat and rabbit kidneys, vascular structures identified in histological sections could be identified in two-dimensional (2D) micro-CT images from the original kidney. Vascular morphology was similar in the two sets of images. Radial geometry quantified by manual analysis of 2D images from micro-CT was consistent with corresponding data generated by light microscopy. However, due to limited spatial resolution when imaging a whole organ using contrast-enhanced micro-CT, only arteries ≥100 μm and ≥60 μm in diameter, for the rat and rabbit respectively, could be assessed. We conclude that it is feasible and valid to use micro-CT to quantify vascular geometry of the renal cortical circulation in both the rat and rabbit. However, a combination of light microscopic and micro-CT approaches are required to evaluate the spatial relationships between intrarenal arteries and veins over an extensive range of vessel size. This article is protected by copyright. All rights reserved.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 17 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 17 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 4 24%
Researcher 3 18%
Student > Master 2 12%
Student > Doctoral Student 1 6%
Unknown 7 41%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 4 24%
Biochemistry, Genetics and Molecular Biology 2 12%
Agricultural and Biological Sciences 1 6%
Chemistry 1 6%
Materials Science 1 6%
Other 0 0%
Unknown 8 47%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 17 May 2019.
All research outputs
#28,611,663
of 34,372,222 outputs
Outputs from Clinical & Experimental Pharmacology & Physiology
#1,466
of 1,816 outputs
Outputs of similar age
#285,032
of 354,451 outputs
Outputs of similar age from Clinical & Experimental Pharmacology & Physiology
#18
of 28 outputs
Altmetric has tracked 34,372,222 research outputs across all sources so far. This one is in the 9th percentile – i.e., 9% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,816 research outputs from this source. They receive a mean Attention Score of 5.0. This one is in the 12th percentile – i.e., 12% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 354,451 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 10th percentile – i.e., 10% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 28 others from the same source and published within six weeks on either side of this one. This one is in the 25th percentile – i.e., 25% of its contemporaries scored the same or lower than it.