↓ Skip to main content

Rapid determination of cell mass and density using digitally controlled electric field in a microfluidic chip

Overview of attention for article published in Lab on a Chip - Miniaturisation for Chemistry & Biology, January 2014

About this Attention Score

  • Good Attention Score compared to outputs of the same age (72nd percentile)
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users
patent
1 patent

Readers on

mendeley
60 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Rapid determination of cell mass and density using digitally controlled electric field in a microfluidic chip
Published in
Lab on a Chip - Miniaturisation for Chemistry & Biology, January 2014
DOI 10.1039/c4lc00795f
Pubmed ID
Authors
Abstract

The density of a single cell is a fundamental property of cells. Cells in the same cycle phase have similar volume, but the differences in their mass and density could elucidate each cell's physiological state. Here we report a novel technique to rapidly measure the density and mass of a single cell using an optically induced electrokinetics (OEK) microfluidic platform. Presently, single cellular mass and density measurement devices require a complicated fabrication process and their output is not scalable, i.e., it is extremely difficult to measure the mass and density of a large quantity of cells rapidly. The technique reported here operates on a principle combining sedimentation theory, computer vision, and microparticle manipulation techniques in an OEK microfluidic platform. We will show in this paper that this technique enables the measurement of single-cell volume, density, and mass rapidly and accurately in a repeatable manner. The technique is also scalable - it allows simultaneous measurement of volume, density, and mass of multiple cells. Essentially, a simple time-controlled projected light pattern is used to illuminate the selected area on the OEK microfluidic chip that contains cells to lift the cells to a particular height above the chip's surface. Then, the cells are allowed to "free fall" to the chip's surface, with competing buoyancy, gravitational, and fluidic drag forces acting on the cells. By using a computer vision algorithm to accurately track the motion of the cells and then relate the cells' motion trajectory to sedimentation theory, the volume, mass, and density of each cell can be rapidly determined. A theoretical model of micro-sized spheres settling towards an infinite plane in a microfluidic environment is first derived and validated experimentally using standard micropolystyrene beads to demonstrate the viability and accuracy of this new technique. Next, we show that the yeast cell volume, mass, and density could be rapidly determined using this technology, with results comparable to those using the existing method suspended microchannel resonator.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 60 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
United States 1 2%
Korea, Republic of 1 2%
Switzerland 1 2%
Unknown 57 95%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 18 30%
Researcher 6 10%
Student > Bachelor 4 7%
Student > Doctoral Student 3 5%
Professor 3 5%
Other 9 15%
Unknown 17 28%
Readers by discipline
Readers by discipline Count As %
Engineering 25 42%
Agricultural and Biological Sciences 6 10%
Physics and Astronomy 3 5%
Chemistry 3 5%
Materials Science 2 3%
Other 4 7%
Unknown 17 28%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 February 2020.
All research outputs
#10,520,236
of 34,363,559 outputs
Outputs from Lab on a Chip - Miniaturisation for Chemistry & Biology
#3,266
of 7,112 outputs
Outputs of similar age
#102,495
of 373,067 outputs
Outputs of similar age from Lab on a Chip - Miniaturisation for Chemistry & Biology
#181
of 365 outputs
Altmetric has tracked 34,363,559 research outputs across all sources so far. This one has received more attention than most of these and is in the 69th percentile.
So far Altmetric has tracked 7,112 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 7.9. This one has gotten more attention than average, scoring higher than 53% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 373,067 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 72% of its contemporaries.
We're also able to compare this research output to 365 others from the same source and published within six weeks on either side of this one. This one is in the 48th percentile – i.e., 48% of its contemporaries scored the same or lower than it.