↓ Skip to main content

A Fully Integrated Nose-on-a-Chip for Rapid Diagnosis of Ventilator-Associated Pneumonia

Overview of attention for article published in IEEE Transactions on Biomedical Circuits and Systems, January 2015
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (71st percentile)
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
1 X user
patent
1 patent

Readers on

mendeley
49 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
A Fully Integrated Nose-on-a-Chip for Rapid Diagnosis of Ventilator-Associated Pneumonia
Published in
IEEE Transactions on Biomedical Circuits and Systems, January 2015
DOI 10.1109/tbcas.2014.2377754
Pubmed ID
Authors
Abstract

Ventilator-associated pneumonia (VAP) still lacks a rapid diagnostic strategy. This study proposes installing a nose-on-a-chip at the proximal end of an expiratory circuit of a ventilator to monitor and to detect metabolite of pneumonia in the early stage. The nose-on-a-chip was designed and fabricated in a 90-nm 1P9M CMOS technology in order to downsize the gas detection system. The chip has eight on-chip sensors, an adaptive interface, a successive approximation analog-to-digital converter (SAR ADC), a learning kernel of continuous restricted Boltzmann machine (CRBM), and a RISC-core with low-voltage SRAM. The functionality of VAP identification was verified using clinical data. In total, 76 samples infected with pneumonia (19 Klebsiella, 25 Pseudomonas aeruginosa, 16 Staphylococcus aureus, and 16 Candida) and 41 uninfected samples were collected as the experimental group and the control group, respectively. The results revealed a very high VAP identification rate at 94.06% for identifying healthy and infected patients. A 100% accuracy to identify the microorganisms of Klebsiella, Pseudomonas aeruginosa, Staphylococcus aureus, and Candida from VAP infected patients was achieved. This chip only consumes 1.27 mW at a 0.5 V supply voltage. This work provides a promising solution for the long-term unresolved rapid VAP diagnostic problem.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 49 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Spain 1 2%
Unknown 48 98%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 10 20%
Researcher 8 16%
Student > Master 7 14%
Student > Bachelor 4 8%
Lecturer 2 4%
Other 5 10%
Unknown 13 27%
Readers by discipline
Readers by discipline Count As %
Engineering 14 29%
Medicine and Dentistry 6 12%
Computer Science 5 10%
Veterinary Science and Veterinary Medicine 1 2%
Chemical Engineering 1 2%
Other 5 10%
Unknown 17 35%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 4. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 25 July 2023.
All research outputs
#9,809,889
of 32,004,021 outputs
Outputs from IEEE Transactions on Biomedical Circuits and Systems
#327
of 864 outputs
Outputs of similar age
#107,196
of 392,552 outputs
Outputs of similar age from IEEE Transactions on Biomedical Circuits and Systems
#7
of 13 outputs
Altmetric has tracked 32,004,021 research outputs across all sources so far. This one has received more attention than most of these and is in the 68th percentile.
So far Altmetric has tracked 864 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.6. This one has gotten more attention than average, scoring higher than 59% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 392,552 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 71% of its contemporaries.
We're also able to compare this research output to 13 others from the same source and published within six weeks on either side of this one. This one is in the 46th percentile – i.e., 46% of its contemporaries scored the same or lower than it.