↓ Skip to main content

A Novel Reagentless Sensing System for Measuring Glucose Based on the Galactose/Glucose-Binding Protein

Overview of attention for article published in Analytical Biochemistry, July 2001
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • High Attention Score compared to outputs of the same age (90th percentile)
  • High Attention Score compared to outputs of the same age and source (91st percentile)

Mentioned by

patent
39 patents

Readers on

mendeley
41 Mendeley
citeulike
1 CiteULike
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
A Novel Reagentless Sensing System for Measuring Glucose Based on the Galactose/Glucose-Binding Protein
Published in
Analytical Biochemistry, July 2001
DOI 10.1006/abio.2001.5131
Pubmed ID
Authors
Abstract

The galactose/glucose-binding protein (GBP) is synthesized in the cytoplasm of Escherichia coli in a precursor form and exported into the periplasmic space upon cleavage of a 23-amino-acid leader sequence. GBP binds galactose and glucose in a highly specific manner. The ligand induces a hinge motion in GBP and the resultant protein conformational change constitutes the basis of the sensing system. The mglB gene, which codes for GBP, was isolated from the chromosome of E. coli using the polymerase chain reaction (PCR). Since wild-type GBP lacks cysteines in its structure, introducing this amino acid by site-directed mutagenesis ensures single-label attachment at specific sites with a sulfhydro-specific fluorescent probe. Site-directed mutagenesis by overlap extension PCR was performed to prepare three different mutants to introduce a single cysteine residue at positions 148, 152, and 182. Since these residues are not involved in ligand binding and since they are located at the edge of the binding cleft, they experience a significant change in environment upon binding of galactose or glucose. The sensing system strategy is based on the fluorescence changes of the probe as the protein undergoes a structural change on binding. In this work a reagentless sensing system has been rationally designed that can detect submicromolar concentrations of glucose. The calibration plots have a linear working range of three orders of magnitude. Although the system can sense galactose as well, this epimer is not a potential interfering substance since its concentration in blood is negligible.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 41 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
Unknown 41 100%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Ph. D. Student 11 27%
Researcher 7 17%
Student > Bachelor 5 12%
Professor 4 10%
Student > Master 4 10%
Other 5 12%
Unknown 5 12%
Readers by discipline
Readers by discipline Count As %
Chemistry 13 32%
Agricultural and Biological Sciences 9 22%
Biochemistry, Genetics and Molecular Biology 5 12%
Engineering 4 10%
Materials Science 2 5%
Other 2 5%
Unknown 6 15%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 12. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 26 October 2021.
All research outputs
#3,406,480
of 30,084,839 outputs
Outputs from Analytical Biochemistry
#168
of 8,863 outputs
Outputs of similar age
#3,699
of 49,417 outputs
Outputs of similar age from Analytical Biochemistry
#5
of 61 outputs
Altmetric has tracked 30,084,839 research outputs across all sources so far. Compared to these this one has done well and is in the 88th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 8,863 research outputs from this source. They receive a mean Attention Score of 4.4. This one has done particularly well, scoring higher than 96% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 49,417 tracked outputs that were published within six weeks on either side of this one in any source. This one has done particularly well, scoring higher than 90% of its contemporaries.
We're also able to compare this research output to 61 others from the same source and published within six weeks on either side of this one. This one has done particularly well, scoring higher than 91% of its contemporaries.