↓ Skip to main content

Impact on Patient Management and Outcome of Switching between 2 Contemporary Sensitive Cardiac Troponin Assays

Overview of attention for article published in Clinical Chemistry, June 2015
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
2 X users

Readers on

mendeley
15 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Impact on Patient Management and Outcome of Switching between 2 Contemporary Sensitive Cardiac Troponin Assays
Published in
Clinical Chemistry, June 2015
DOI 10.1373/clinchem.2015.238089
Pubmed ID
Authors
Abstract

Myocardial infarction is characterized by an increase of cardiac troponin I (cTnI) above the 99th percentile of a reference population. Our hospital switched from 1 contemporary cTnI assay to another and observed a doubling of cTnI results above the assays' respective 99th percentile cutoffs. We investigated the potential impact on inpatient management and outcomes. We performed a retrospective cohort study of 45498 individuals with ≥1 cTnI result between January 2013 and June 2014. The Dimension cTnI assay was used in 2013; the Abbott Architect cTnI assay was used in 2014. Before switching cTnI assays, 19.2% (4742/30 872) of patients had at least 1 of the first 3 cTnIs above the 99th percentile (0.07 μg/L). After switching to the Architect cTnI assay, 31.4% (4034/14 626) of patients had at least 1 cTnI above the 99th percentile (0.03 μg/L). This increase was due to the difference in the assays' 99th percentile cutoffs. Having an increased cTnI reported on the Architect assay that would not have been reported as such on the Dimension assay (0.03-0.06 μg/L) correlated with increased inpatient mortality, length of stay, non-ST elevation myocardial infarction diagnosis, therapeutic heparin use, and percutaneous coronary intervention, relative to individuals with cTnI <0.03 μg/L. The changes observed in patient outcomes and management were likely due to the increased sensitivity and lower 99th percentile cutoff of the Architect assay. It is important to recognize the potential impact that differences in sensitivity and assay configuration may have on patient management.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 15 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
United States 1 7%
Australia 1 7%
Unknown 13 87%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Other 3 20%
Professor 3 20%
Student > Master 2 13%
Researcher 2 13%
Student > Ph. D. Student 1 7%
Other 1 7%
Unknown 3 20%
Readers by discipline
Readers by discipline Count As %
Medicine and Dentistry 9 60%
Agricultural and Biological Sciences 2 13%
Biochemistry, Genetics and Molecular Biology 1 7%
Unknown 3 20%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 20 April 2015.
All research outputs
#15,329,087
of 22,799,071 outputs
Outputs from Clinical Chemistry
#6,420
of 7,380 outputs
Outputs of similar age
#157,031
of 267,533 outputs
Outputs of similar age from Clinical Chemistry
#26
of 39 outputs
Altmetric has tracked 22,799,071 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 7,380 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 6.4. This one is in the 9th percentile – i.e., 9% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 267,533 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 32nd percentile – i.e., 32% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 39 others from the same source and published within six weeks on either side of this one. This one is in the 25th percentile – i.e., 25% of its contemporaries scored the same or lower than it.