↓ Skip to main content

Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement

Overview of attention for article published in Kidney International, August 1997
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (68th percentile)
  • Good Attention Score compared to outputs of the same age and source (75th percentile)

Mentioned by

patent
3 patents

Readers on

mendeley
25 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Article details
Title
Precise quantification of dialysis using continuous sampling of spent dialysate and total dialysate volume measurement
Published in
Kidney International, August 1997
DOI 10.1038/ki.1997.364
Pubmed ID
Authors
Abstract

The "gold standard" method to evaluate the mass balances achieved during dialysis for a given solute remains total dialysate collection (TDC). However, since handling over 100 liter volumes is unfeasible in our current dialysis units, alternative methods have been proposed, including urea kinetic modeling, partial dialysate collection (PDC) and more recently, monitoring of dialysate urea by on-line devices. Concerned by the complexity and costs generated by these devices, we aimed to adapt the simple "gold standard" TDC method to clinical practice by diminishing the total volumes to be handled. We describe a new system based on partial dialysate collection, the continuous spent sampling of dialysate (CSSD), and present its technical validation. Further, and for the first time, we report a long-term assessment of dialysis dosage in a dialysis clinic using both the classical PDC and the new CSSD system in a group of six stable dialysis patients who were followed for a period of three years. For the CSSD technique, spent dialysate was continuously sampled by a reversed automatic infusion pump at a rate of 10 ml/hr. The piston was automatically driven by the dialysis machine: switched on when dialysis started, off when dialysis terminated and held during the by pass periods. At the same time the number of production cycles of dialysate was monitored and the total volume of dialysate was calculated by multiplying the volume of the production chamber by the number of cycles. Urea and creatinine concentrations were measured in the syringe and the masses were obtained by multiplying this concentration by the total volume. CSSD and TDC were simultaneously performed in 20 dialysis sessions. The total mass of urea removed was calculated as 58038 and 60442 mmol/session (CSSD and TDC respectively; 3.1 +/- 1.2% variation; r = 0.99; y = 0.92x -28.9; P < 0.001). The total mass of creatinine removed was 146,941,143 and 150,071,195 mumol/session (2.2 +/- 0.9% variation; r = 0.99; y = 0.99x + 263; P < 0.001). To determine the long-term clinical use of PDC and CSSD, all the dialysis sessions monitored during three consecutive summers with PDC (during 1993 and 1994) and with CSSD (1995) in six stable dialysis patients were included. The clinical study comparing PDC and CSSD showed similar urea removal: 510 +/- 59 during the first year with PDC and 516 +/- 46 mmol/dialysis session during the third year, using CSSD. Protein catabolic rate (PCR) could be calculated from total urea removal and was 1.05 +/- 0.11 and 1.05 +/- 0.09 g/kg/day with PDC and CSSD for the same periods. PCR values were clearly more stable when calculated from the daily dialysate collections than when obtained with urea kinetic modeling performed once monthly. We found that CSSD is a simple and accurate method to monitor mass balances of urea or any other solute of clinical interest. With CSSD, dialysis efficacy can be monitored at every dialysis session without the need for bleeding a patient. As it is external to the dialysis machine, it can be attached to any type of machine with a very low cost. The sample of dialysate is easy to handle, since it is already taken in a syringe that is sent directly to the laboratory. The CSSD system is currently in routine use in our unit and has demonstrated its feasibility, low cost and high clinical interest in monitoring dialysis patients.

Login to access the Attention Digest and the Sentiment Analysis related to this output.

Timeline Attention over time Attention Score history
Login to access the full charts related to this output.
Activity
Login to access the full charts related to this output.
Mendeley demographics

Mendeley demographics

The data shown below were compiled from readership statistics for 25 Mendeley readers of this research output. Click here to see the associated Mendeley record.
Login to view Mendeley reader trends over time.

Geographical breakdown

Geographical breakdown
Country Count As %
France 1 4%
Unknown 24 96%

Demographic breakdown

Readers by professional status
Readers by professional status Count As %
Student > Bachelor 6 24%
Student > Ph. D. Student 4 16%
Researcher 4 16%
Student > Postgraduate 2 8%
Student > Doctoral Student 1 4%
Other 1 4%
Unknown 7 28%
Readers by discipline
Readers by discipline Count As %
Engineering 6 24%
Medicine and Dentistry 5 20%
Nursing and Health Professions 2 8%
Pharmacology, Toxicology and Pharmaceutical Science 1 4%
Biochemistry, Genetics and Molecular Biology 1 4%
Other 3 12%
Unknown 7 28%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 6. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 04 January 2023.
All research outputs
#6,086,972
of 27,777,630 outputs
Outputs from Kidney International
#2,757
of 8,424 outputs
Outputs of similar age
#5,338
of 31,928 outputs
Outputs of similar age from Kidney International
#3
of 28 outputs
Altmetric has tracked 27,777,630 research outputs across all sources so far. This one has received more attention than most of these and is in the 74th percentile.
So far Altmetric has tracked 8,424 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 10.8. This one has gotten more attention than average, scoring higher than 59% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 31,928 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 68% of its contemporaries.
We're also able to compare this research output to 28 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 75% of its contemporaries.